3-2. Outdoor fan control

¢ Outdoor fan motor
This outdoor unit has a DC fan motor. (Control method is different between AC and DC motors.)
¢ Fan speed
 Model: AOTG30KMTC
Fan speed is defined by outdoor temperature and compressor frequency.
• Outside air temperature zone selection
Fan step
Y zone
S-HIGH2
S-HIGH1
HIGH3
HIGH2
HIGH1
MED2
MED1
LOW2
LOW1
NOTE: After defrost control on the heating mode, the fan speed is kept higher regardless of the
compressor frequency.
Fan speed after defrost control: 900 rpm
3-2. Outdoor fan control
Outside air
temperature rises
21°C
12°C
2°C
-8°C
Cooling
Heating
Z zone
800
800
500
750
400
700
360
620
320
500
280
400
250
Outside air
temperature drops
Y zone
Z zone
F zone
G zone
H zone
Dry
Cooling or dry at low outdoor temp.
Y or Z zone
F zone
900
900
830
830
320
800
620
280
550
450
280