Carrier CH16NA Installation Instructions Manual page 9

Split-system heat pump with r-410a refrigerant 1-1/2 to 5 tons
Table of Contents

Advertisement

18
24
CAP**1814AL*
---
CAP**2414AL*
CAP**2414AL*
---
CAP**2417AL*
CAP**2417AL*
---
CAP**2517AL*
CNPV*1814AL*
---
CAP**3014AL*
CNPV*2414AL*
---
CAP**3017AL*
CNPV*2417AL*
---
CNPV*2414AL*
CSPH*2412AL*
---
CNPV*2417AL*
FB4CNF018L
---
CNPV*3014AL*
FB4CNF024L
---
CNPV*3017AL*
FB4CNP018L
---
CSPH*2412AL*
FB4CNP024L
---
CSPH*3012AL*
FFMANP018
---
FB4CNF030L
FFMANP019
---
FB4CNP030L
FFMANP024
---
FFMANP024
FFMANP025
---
FFMANP025
FPMAN*018
---
FFMANP030
FPMAN*024
---
FFMANP031
FPMBN*018
---
FPMAN*024
FPMBN*024
---
FPMAN*030
FV4CN(B,F)003L
---
FPMBN*024
FV4CNF002L
---
FPMBN*030
FX4DNF019L
---
FV4CN(B,F)003L
FX4DNF025L
---
FV4CNF002L
FX4DN(B,F)031L
FX4DN(B,F)037L
FX4DNF025L
LIQUID PRESSURE AT
SERVICE VALVE
(PSIG)
251
259
266
274
283
291
299
308
317
326
335
345
354
100
364
102
374
104
384
106
395
108
406
110
416
112
427
114
439
116
450
118
462
120
474
122
486
124
499
126
511
128
Table 4 – Additional Subcooling Required for CH14 Models
Subcooling Delta from Rating Plate Value
Outdoor Unit Tonnage
Indoor Unit | Additional Subcooling Required
30
---
CAP**3014AL*
---
CAP**3614AL*
---
CAP**3017AL*
---
CAP**3617AL*
+5
CAP**3614AL*
---
CAP**3621AL*
---
CAP**3617AL*
---
CAP**4221AL*
---
CAP**3621AL*
---
CAP**4224AL*
---
CAP**3717AL*
+5
CNPV*3617AL*
---
CAP**3721AL*
+5
CNPV*3621AL*
---
CNPV*3014AL*
---
CNPV*4217AL*
---
CNPV*3017AL*
---
CNPV*4221AL*
---
CNPV*3617AL*
---
CSPH*3612AL*
---
CNPV*3621AL*
---
CSPH*4212AL*
---
CSPH*3012AL*
---
FB4CNF036L
---
CSPH*3612AL*
---
FB4CNF042L
---
FB4CNF030L
---
FB4CNP036L
---
FB4CNF036L
---
FB4CNP042L
---
FB4CNP030L
---
FFMANP036
---
FB4CNP036L
---
FFMANP037
---
FFMANP030
---
FPMAN*036
---
FFMANP031
---
FV4CN(B,F)003L
---
FFMANP036
---
FV4CN(B,F)005L
---
FFMANP037
---
FV4CNB006L
---
FPMAN*030
---
FV4CNF002L
---
FPMAN*036
---
FX4DN(B,F)037L
---
FPMBN*030
---
FX4DN(B,F)043L
+5
FV4CN(B,F)003L
---
FX4DN(B,F)049L
---
FV4CN(B,F)005L
+5
FV4CNF002L
---
FX4DN(B,F)031L
---
FX4DN(B,F)037L
+3
FX4DN(B,F)043L
+3
Table 5 – Required Liquid Line Temperatures _F
REQUIRED SUBCOOLING TEMPERATURE (° F)
8
10
76
74
78
76
80
78
82
80
84
82
86
84
88
86
90
88
92
90
94
92
96
94
98
96
98
100
102
104
106
108
110
112
114
116
118
120
122
124
126
36
42
---
CAP**4221AL*
---
---
CAP**4224AL*
---
---
CAP**4321AL*
+5
---
CAP**4817AL*
+5
---
CAP**4821AL*
+3
---
CAP**4824AL*
+3
---
CNPV*4217AL*
---
---
CNPV*4221AL*
---
---
CNPV*4821AL*
---
---
CNPV*4824AL*
---
---
CSPH*4212AL*
---
---
CSPH*4812AL*
---
---
FB4CNF042L
---
---
FB4CNF048L
---
---
FB4CNP042L
---
---
FB4CNP048L
---
---
FV4CN(B,F)003L
---
---
FV4CN(B,F)005L
+3
---
FV4CNB006L
+5
+3
FX4DN(B,F)043L
---
+5
FX4DN(B,F)049L
+3
---
FX4DN(B,F)061L
+5
---
---
+3
12
14
72
70
74
72
76
74
78
76
80
78
82
80
84
82
86
84
88
86
90
88
92
90
94
92
96
94
98
96
100
98
102
100
104
102
106
104
108
106
110
108
112
110
114
112
116
114
118
116
120
118
122
120
124
122
9
48
60
CAP**4817AL*
---
CAP**6021AL*
CAP**4821AL*
---
CAP**6024AL*
CAP**4824AL*
---
CAP**6124AL*
CAP**6021AL*
---
CNPV*6024AL*
CAP**6024AL*
---
CSPH*6012AL*
CAP**6124AL*
+3
FB4CNP060L
CNPV*4821AL*
---
FV4CNB006L
CNPV*4824AL*
---
FX4DN(B,F)061L
CNPV*6024AL*
---
CSPH*4812AL*
---
CSPH*6012AL*
---
FB4CNF048L
---
FB4CNP048L
---
FB4CNP060L
---
FV4CN(B,F)005L
---
FV4CNB006L
+3
FX4DN(B,F)049L
---
FX4DN(B,F)061L
+3
16
18
68
66
70
68
72
70
74
72
76
74
78
76
80
78
82
80
84
82
86
84
88
86
90
88
92
90
94
92
96
94
98
96
100
98
102
100
104
102
106
104
108
106
110
108
112
110
114
112
116
114
118
116
120
118
---
---
---
---
---
---
---
---