Carrier CNPVP, CNRVP Installation Instructions Manual

Carrier CNPVP, CNRVP Installation Instructions Manual

Cnpvp/cnrvp series cased n coils uplow-downflow heating -cooling

Advertisement

CNPVP
CNRVP
NOTE: Read the entire instruction manual before starting the

installation.

TABLE OF CONTENTS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock, or other
conditions which may cause personal injury or property damage.
Consult a qualified installer, service agency, or your distributor or
branch for information or assistance. The qualified installer or
agency must use factory- -authorized kits or accessories when
modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses and work gloves. Use
quenching cloth for brazing operations. Have fire extinguisher
available. Read these instructions thoroughly and follow all
warning or cautions attached to the unit. Consult local building
codes and
National Electrical Code (NEC) for special
requirements.
It is important to recognize safety information. This is the safety
alert symbol
. When you see this symbol on the unit and in
instructions or manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, CAUTION,
and NOTE. These words are used with the safety- -alert symbol.
DANGER identifies the most serious hazards which will result in
severe personal injury or death. WARNING signifies hazards
which could result in personal injury or death. CAUTION is used
to identify unsafe practices which may result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability, or
operation.
IMPORTANT: Nitrogen can leak out through the hole that the
needle pierced in the plugs. This does not indicate a leaking coil
nor warrant return of the coil.
Installation Instructions
PAGE
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury
1
or death.
1
Before installing, modifying or servicing system, always turn
off main power to system. There may be more than one
1
disconnect switch. Lock out and tag switch with a suitable
2
warning label.
2
3
!
5
5
PERSONAL INJURY HAZARD
5
Failure to follow this caution may result in personal injury.
5
This coil contains Nitrogen precharge of 15 PSIG. Release of this
6
pressure through the center of the rubber plugs is required before
removing the plugs.
!
CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and
wear appropriate protective clothing and gloves when handling
parts.

INTRODUCTION

Use this instruction manual to install indoor coils on upflow or
downflow furnaces. Do not install coil in horizontal position.
Models CNPVP/CNRVP are enclosed in a painted casing and both
coils have factory- -installed TXV's. CNPVP models are used with
Puron (R- -410A) systems and CNRVP models are used with R- -22
systems.
NOTE: Models with tin- -plated copper coils, "T" in the 11th
position of the model number, are installed the same as standard
copper coils.
INSTALLATION
These units can be installed in multiple configurations. Before
installation, there are several performance requirements that must
be considered because poor installation can negatively alter
performance. This section will briefly discuss those factors.
Cased N Coils
Upflow --- Downflow
Heating --- Cooling
WARNING
CAUTION
CAUTION

Advertisement

loading

Summary of Contents for Carrier CNPVP, CNRVP

  • Page 1: Table Of Contents

    Cased N Coils CNPVP Upflow --- Downflow CNRVP Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the WARNING installation. TABLE OF CONTENTS ELECTRICAL SHOCK HAZARD PAGE Failure to follow this warning could result in personal injury SAFETY CONSIDERATIONS .
  • Page 2: Inspect Equipment

    Airflow CNRVP Models: These coils have a factory- -installed hard- -shutoff TXV designed Airflow amount and distribution are vital to adequate system only for use with R- -22 refrigerant. Use only with outdoor units performance. Problems that can be experienced with incorrect designed for R- -22.
  • Page 3: Installation Of Furnace Coils

    NOTE: When CNPVT/CNRVT (transition coils) are applied to Field-supplied same width furnace, remove block- -off plates at casing base by Plenum removing 2 screws per plate from side of casing. See Fig. 3. ⁄ ″ (487) ⁄ ″ Field (13) Coil Support Shelf ⁄...
  • Page 4: Downflow Cased Coil Installation

    2 1/4” (57) Field Fabricated Block-off Plate ALTERNATIVE ALTERNATIVE ALTERNATIVE WRONG MODELS: T036, T042, T048, AND T060 ONLY A08337 Fig. 4 - - Alternative Coil Mounting Positions Coil Casing Width 3/4” (19) Rear Bracket Flanges (Where Shown) 19 1/2” (495) (Outside) 2 1/4”...
  • Page 5: Connect Refrigerant Piping

    3. Coils that under- -hang (narrower than furnace) must have a 7. Continue with normal installation practices. See Connect 2 1/4” (57 mm) long (minimum) field- -fabricated transition Refrigerant Piping. between furnace and N- -coil casing. Connect Refrigerant Piping 4. Coils that overhang (wider than furnace) do not require a Use accessory tubing package or field- -supplied tubing of transition in downflow application.
  • Page 6: Humidifier Application

    fittings be used on the condensate pan. Do not over- -tighten. Finger tighten plus 1- -1/2 turns. Be sure to install plastic plug in unused condensate drain fitting. NOTE: If unit is located in or above a living space where damage may result from condensate overflow, a field- -supplied, external Supply condensate pan should be installed under the entire unit, and a...