Summary of Contents for ESI ES3247

  • Page 1 ES3247 3 Channel Programmer User and Installation Instructions...
  • Page 3 INDEX User Instructions What is a Channel Programmer? Introduction to the 3 Channel Programmer Programming the Unit The Factory-set Programme Changing the Programme Linking Central Heating & Hot Water Times Operating the Unit Choosing the Operating Mode Using the Advance Function Using the +HR Boost Function Basic Settings Setting the Time &...
  • Page 4: Table Of Contents

    INDEX Installation Instructions Technical Data Installation Safety Instructions, Maintenance & Safety Notice Pre-Installation Unit Set Up Fitting the Back Plate New Installations Existing Installations Wiring Diagram Fitting the Programmer Commissioning Configuration...
  • Page 5 User Instructions...
  • Page 6 What is a Channel Programmer?... An explanation for householders Programmers allow you to set ‘On’ and ‘Off’ time periods. Some models switch the Central Heating and domestic Hot Water on and off at the same time, while others allow the domestic Hot Water and Heating to come on and go off...
  • Page 7 Introduction to the 3 Channel Programmer This programmer can automatically switch your Central Heating or Hot Water ON and OFF up to 3 times a day, at whatever times you choose. Timekeeping is maintained through power interruptions by a non replaceable battery designed to last for the lifetime of the programmer and the clock is automatically put forward 1 hour at 1:00am on the last Sunday of March and back 1 hour at 2:00am on the last Sunday of October.
  • Page 8 Programming the Unit The Factory-Set Programme This is the factory-set programme built into the unit. If the user changes from the factory-set programme and wishes to return to it, pressing the reset button with a non metallic pointed tool will return the unit to the factory-set programme.
  • Page 9 Fig. 1 2. Press the +/- buttons (4) to alter the ON time. 3. Press the NEXT button (5), and the display will now show 1 OFF (3). 4. Press the +/- buttons (4) to alter the OFF time. 5. Press the NEXT button (5) to access remaining ON/OFF periods and alter in same manner as above.
  • Page 10 Linking Central Heating & Hot Water Times The last letter of the configuration (either U or A) will be L if the Central Heating and Hot Water programmes have been linked. In this mode the Hot Water (and second Central Heating channel in 3 channel programmers) will run from the Central Heating 1 programme, so changes to the programme need only be made once and this will affect both Central Heating and Hot Water (and second...
  • Page 11 Using the Advance Function The ADVANCE function allows the user to move to the next ON/OFF programme for a “one off” event, without having to change the programme or use the ON or OFF buttons. NB: The ADVANCE function is only available when the programme is in AUTO or ALL DAY operating modes.
  • Page 12 Using the +HR Boost Function The +HR function allows the user to have up to 3 hours of extra Central Heating or Hot Water, without having to change the programme or use the ON or OFF buttons. NB: The +HR function is only available when the programme is in AUTO, ALL DAY or OFF operating modes.
  • Page 13 Basic Settings Setting the Time (refer to fig.4) 1. Press the SET button (1) once. The configuration setting will appear on the screen. (E.G. 2PU) 2. Press the SET button (1) again. The clock icon (2) on the screen will flash. 3.
  • Page 14 Setting the Backlight The backlight can either be set permanently ON or OFF. The programmer backlight is pre-set to be permanently OFF. When the backlight is permanently OFF, the backlight will turn ON for 15 seconds when + or – button is pressed, then turn OFF automatically. To change setting to permanently ON, press SET repeatedly until L IR is displayed.
  • Page 15: Installation Instructions

    Installation Instructions...
  • Page 16: Technical Data

    Technical Data...
  • Page 17: Installation Safety Instructions, Maintenance & Safety Notice

    Installation Safety Instructions The unit must be installed by a suitably qualified person in accord- ance with the latest IEE Wiring Regulations. Isolate mains supply before commencing installation. Please read all instructions before proceeding. Ensure that the fixed wiring connections to the mains supply is via a fuse rated at not more than 6 amps and class ‘A’...
  • Page 18: Pre-Installation Unit Set Up

    Pre-Installation Unit Set Up Before installing, set the bank of 4 DIP Switches on the back to configure the unit according to the chart below: Gravity Pumped 7 Day 24 Hr 5/2 Day 3 On/Off 2 On/Off (DIP Switches shown in Factory Default Positions. PUMPED: allows independent control of CH and HW.
  • Page 19: New Installations

    Other control components shown in the diagram i.e. Valves, Room Stats etc are general representations only. However, the wiring detail can be applied to the corresponding model of most manufac- turers e.g. Horstmann, Honeywell, Danfoss Randall, Drayton, ESi Controls etc. Existing Installations 1.
  • Page 20: Wiring Diagram

    Wiring Diagram...
  • Page 21: Fitting The Programmer

    Fitting the Programmer 1. Loosen the two ‘captive’ retaining screws on the bottom of the back plate. 2. Now fit the programmer to the back plate, ensuring the lugs of the back plate engage with the slots on the programmer. 3.
  • Page 22: Configuration

    Configuration When setting time, date or changing programme times the first screen displayed indicates the configuration. The 24 hour, 5 day/2day, or 7 day programming options as set up by the installer can also be verified at this stage by how the Monday to Sunday indicators are displayed.
  • Page 24 ESi Controls Limited sales@esicontrols.co.uk www.esicontrols.co.uk Version 3.1...