7.2.4

Setting of Bearing Pulses from Scanner Unit (Output Pulse)

Set the output value of bearing pulses from the scanner unit. The system can set
2048 pulses or 4096 pulses. This setting is enabled only when the scanner unit of
25 or 30 kW is used.
Procedures
1)
Open the Serviceman Menu.
2)
Perform the following menu open procedure to open the Output
Pulse setting menu.
  
  
3)
Set the number of pulses to be output by the scanner unit.
2. Installation Menu
→ 
9. Next
→ 
2. TNI Blank
2. Make Sector
ENT
ENT
1. Adjust Menu
4. TXRX Adjustment
→ 
→ 
6. Output Pulse
i
:2048 pulses per antenna rotation (Recommended value)
2048
:4096 pulses per antenna rotation
4096
i. If a 10 kW antenna is used, 2048 is always set.
7- 18
>
7.2 SETTINGS
button in the menu.
button.
button.