INSTALLATION INSTRUCTIONS
In the state of Massachusetts:
S
This product must be installed by a licensed plumber or
gas fitter.
S
When flexible connectors are used, the maximum
length shall not exceed 36 in. (914 mm).
S
When lever type gas shutoffs are used they shall be
T−handle type.
S
The use of copper tubing for gas piping is not
approved by the state of Massachusetts.
Electrical Connections
S
US: Current edition of the National Electrical Code
(NEC) NFPA 70
S
CANADA: Current edition of the Canadian Electrical
Code CSA C22.1
Condensate Drain Connection
US: Current edition of the National Standard Plumbing
Code, Section 8.7.
Canada: Current edition of the National Plumbing Code of
Canada
IMPORTANT: Gas furnaces manufactured on or after
May 1, 2017 are not permitted to be used in Canada for
heating of buildings or structures under construction.
ELECTROSTATIC DISCHARGE
(ESD) PRECAUTIONS

PROCEDURE

CAUTION
!
FURNACE RELIABILITY HAZARD
Failure to follow this caution may result in unit
component damage.
Electrostatic
discharge
components.
Take
precautions
installation and servicing to protect the furnace
electronic
control.
electrostatic discharges from personnel and hand
tools which are held during the procedure. These
precautions will help to avoid exposing the control to
electrostatic discharge by putting the furnace, the
control, and the person at the same electrostatic
potential.
1. Disconnect all power to the furnace. Multiple disconnects
may be required. DO NOT TOUCH THE CONTROL OR
ANY WIRE CONNECTED TO THE CONTROL PRIOR
TO DISCHARGING YOUR BODY'S ELECTROSTATIC
CHARGE TO GROUND.
2. Firmly touch the clean, unpainted, metal surface of the
furnace chassis which is close to the control. Tools held
in a person's hand during grounding will be satisfactorily
discharged.
3. After touching the chassis, you may proceed to service
the control or connecting wires as long as you do nothing
to recharge your body with static electricity (for example;
440 01 6001 05
can
affect
electronic
during
furnace
Precautions
will
prevent
Specifications subject to change without notice.
DO NOT move or shuffle your feet, do not touch
ungrounded objects, etc.).
4. If you touch ungrounded objects (and recharge your
body with static electricity), firmly touch a clean,
unpainted metal surface of the furnace again before
touching control or wires.
5. Use this procedure for installed and uninstalled
(ungrounded) furnaces.
6. Before removing a new control from its container,
discharge your body's electrostatic charge to ground to
protect the control from damage. If the control is to be
installed in a furnace, follow items 1 through 4 before
bringing the control or yourself in contact with the
furnace. Put all used and new controls into containers
before touching ungrounded objects.
7. An ESD service kit (available from commercial sources)
may also be used to prevent ESD damage.
ACCESSORIES
See Specification Sheet for a list of accessories for this
product.
Table 1 – Factory−Supplied Installation Parts
DESCRIPTION
Air Intake Pipe Flange
Vent Pipe Flange
Pipe Flange Gaskets
Sharp Tip Screws (Vent and Inlet Flanges)
Vent Pipe Coupling
Vent Pipe Coupling Clamps
Pressure Switch Tube
Rubber Drain Elbow
Drain Elbow Clamps
1/2-in. CPVC to 3/4-in. PVC Pipe Adapter
Gas Line Grommet
Junction Box Cover
Junction Box Base
Green Ground Screw
Blunt Tip Screws (Junction Box)
Thermostat Wire Grommet
Drain Extension Tube (Z-pipe)
(Provided separately in furnace)
Table 2 – Minimum Clearances to Combustible Materials
for All Units
POSITION
REAR
FRONT (Combustion air openings
in furnace and in structure)
Recommended for service
All Sides of Supply Plenum
Sides
Vent
Top of Furnace
*Consult local building codes
Gas Furnace: R9MSB
QUANTITY
1
1
2
10
1
2
1
1
4
1
1
1
1
1
3
1
1
CLEARANCE
0
1 in. (25 mm)
*24 in. (610 mm)
*1 in. (25 mm)
0
0
1 in. (25 mm)
5