International comfort products R9MSB0801716 Installation Instructions Manual page 40

Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS
Table 12 – Approved Combustion-Air and Vent Pipe, Fitting and Cement Materials (U.S.A. Installations)
1. All pipe, fittings, primers*, and solvents* must conform to American National Standards Institute (ANSI)
standards and American Society for Testing and Materials (ASTM) standards or ULC S636 where required
by code.
USA
2. See Table below for approved materials for use in the U.S.A.
3. ULC S636 vent systems must be composed of pipe, fittings, cements, and primers from the same supplier.
4. Factory accessory concentric vent kits are ULC S636 listed.
1. Installation in Canada must conform to the requirements of CAN/CSA B149 code.
2. Vent systems must be composed of pipe, fittings, cements, and primers from the same supplier and listed
to ULC S636.
CANADA
3. Not all materials below may be approved or listed to ULC S636.
4. Royal Pipe and IPEX are approved suppliers of ULC S636 pipe, fittings, cements and primers*.
5. Factory accessory concentric vent kits are ULC S636 listed for use with Royal Pipe and IPEX venting
systems.
Material
Description
Pressure Pipe
DWV
Cellular Core
SDR 26
PVC
SDR21
IPEX
Royal Pipe
ABS
Cellular Core
ABS
DWV
Pressure Pipe
SDR
CPVC
IPEX
Royal Pipe
*Colored or tinted solvents or primers must be used where required by code in the USA
†ABS plastic does not require a primer before solvent cementing. A cleaner for ABS is recommended to remove any surface
residue. ABS cleaners are not subject to ASTM standards.
Polypropylene
Poly Pror
NOTE: Polypropylene vent systems are UL−1738 and ULC S636 listed and assembled using mechanical fastening systems
supplied by the vent manufacturer.
Locating the Vent Termination
General
NOTE:
Termination Requirements for the Provinces of
Alberta and Saskatchewan are located at the end of this
section.
Combustion−air inlet pipe (direct vent/2−pipe system only) and
vent pipe must terminate outside structure, either through
sidewall or roof.
For vent termination clearance, references to National codes
are shown in Figure 52 for Direct Vent/2−Pipe system and
Figure 53
for
Ventilated
Vent/1−Pipe system. For exterior termination arrangements,
refer to Figure 54 for Direct Vent/2−Pipe system and Figure 55
for Ventilated Combustion Air/Non− Direct/1−Pipe system.
Contact Local code authorities for other requirements to and/or
exemptions from the National codes shown in the figures.
Roof termination is the recommended termination location.
Roof
terminations provide better performance against
sustained prevailing winds. The roof location is preferred since
the vent and combustion air system is less susceptible to
damage or contamination. The termination is usually located
away from adjacent structures or other
40
MATERIALS
Type
Schedule 40
Schedule 40
Schedule 40
N/A
N/A
Schedule 40
Schedule 40
Schedule 40
Schedule 40
Schedule 40
N/A
Schedule 40
Schedule 40
Approved Manufacturer
M & G Dura Vent
Combustion
Air/Non−direct
obstacles such as
Specifications subject to change without notice.
ASTM or ULC Specification
Pipe
Fittings
D1785
D2466
D2665
D2665
F891
N/A
D2241
N/A
D2241
N/A
ULC S636
ULC S636
ULC S636
ULC S636
D2661
D2661
F628
N/A
F441
F438
F442
N/A
ULC S636
ULC S636
ULC S636
ULC S636
inside corners, windows, doors or other appliances. It is less
prone to icing conditions, and it often has less visible vent
vapors.
Sidewall terminations may require sealing or shielding of
building surfaces with a corrosive resistance material due to the
corrosive properties of combustion products from the vent
system, as well as protection of adjacent structures.
NOTE: (Direct Vent/2−Pipe system ONLY) A factory accessory
termination kit MUST be used. See Table 11 for available
options.
NOTICE
RECOMMENDED
TERMINATIONS
It is recommended that sidewall vent terminations of over
24 inches (0.6 M) in length or rooftop vent terminations
of over 36 inches (1 M) in vertical length be supported by
EITHER the Direct Vent Termination Kit shown in Table
11 or by field-supplied brackets or supports fastened to
the structure.
Gas Furnace: R9MSB
Solvents
Cements
Primers*
F656
D2564
ULC S636
ULC S636
ULC S636
ULC S636
Clear Cleaner
D2235
For ABS
F656
F493
ULC S636
ULC S636
ULC S636
ULC S636
Solvents
Cements
Primers
Not Permitted
Not Permitted
SUPPORT
FOR
VENT
440 01 6001 05