Electrostatic Discharge (Esd) Precautions - International comfort products A Series Installation Instructions Manual

Single-stage, 35-in. tall high efficiency, condensing, ultra low nox gas furnace
Table of Contents

Advertisement

ELECTROSTATIC DISCHARGE (ESD)
PRECAUTIONS PROCEDURE
CAUTION
!
FURNACE RELIABILITY HAZARD
Failure to follow this caution may result in unit component
damage.
Electrostatic discharge can affect electronic components.
Take precautions during furnace installation and servicing
to protect the furnace electronic control. Precautions will
prevent electrostatic discharges from personnel and hand
tools which are held during the procedure. These
precautions will help to avoid exposing the control to
electrostatic discharge by putting the furnace, the control,
and the person at the same electrostatic potential.
1. Disconnect all power to the furnace. Multiple disconnects
may be required. DO NOT TOUCH THE CONTROL
OR ANY WIRE CONNECTED TO THE CONTROL
PRIOR
TO
DISCHARGING
ELECTROSTATIC CHARGE TO GROUND.
2. Firmly touch the clean, unpainted, metal surface of the fur-
nace chassis which is close to the control. Tools held in a
person's hand during grounding will be satisfactorily dis-
charged.
3. After touching the chassis, you may proceed to service the
control or connecting wires as long as you do nothing to
recharge your body with static electricity (for example; DO
NOT move or shuffle your feet, do not touch ungrounded
objects, etc.).
4. If you touch ungrounded objects (and recharge your body
with static electricity), firmly touch a clean, unpainted metal
surface of the furnace again before touching control or
wires.
5. Use this procedure for installed and uninstalled (ungroun-
ded) furnaces.
6. Before removing a new control from its container, discharge
your body's electrostatic charge to ground to protect the
control from damage. If the control is to be installed in a
furnace, follow items 1 through 4 before bringing the con-
trol or yourself in contact with the furnace. Put all used and
new controls into containers before touching ungrounded
objects.
7. An ESD service kit (available from commercial sources)
may also be used to prevent ESD damage.
ACCESSORIES
See Specification Sheet for a list of accessories for this product.
LOCATION
CAUTION
!
PERSONAL RELIABILITY HAZARD
Failure to follow this caution may result in unit component
damage.
Furnace may not be used for heating buildings under
construction.
IMPORTANT: Clearances for Condensate Trap
Before locating furnace, refer to condensate trap installation
instructions section for required clearances for trap installation.
440 01 4601 01
NOTE: Local codes may require a drain pan and condensate
tray when a condensing furnace is installed over a finished
ceiling.
YOUR
BODY'S
General
These furnaces are shipped with materials to assist in proper
furnace installation. These materials are shipped in the main blower
compartment.
Loose parts bag contents (Table 2).
This furnace must:
S be installed so the electrical components are protected from
water.
S not be installed directly on any combustible material other than
wood flooring (refer to SAFETY CONSIDERATIONS).
S be located close to the chimney or vent and attached to an air
distribution system. Refer to Air Ducts section.
S be provided ample space for servicing and cleaning. Always
comply with minimum fire protection clearances (Table 1).
Specifications subject to change without notice.
Representative drawing only, some models may vary.
Fig. 6 - - 15" Trap Clearance in Horizontal Application
FACTORY SUPPLIED
CONDENSATE
FLOAT SWITCH
Representative drawing only, some models may vary.
Fig. 7 - - Trap Clearance in Upflow Application
A190356
FACTORY SUPPLIED
3/4" PVC TEE DRAIN
DRAIN TEE CAN BE
ROTATED FORWARD
FOR NARROW
INSTALLATIONS
TO OPEN DRAIN
A190317
7