Superior CF5500-CMN Installation Instructions Manual

Standard series unvented decorative gas fireplaces
Hide thumbs Also See for CF5500-CMN:

Advertisement

RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline
or other flammable vapors or liquids in the vicinity
of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone.
Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
INSTALLATION
INSTRUCTIONS
Unvented Decorative Gas Fireplaces
P/N 904538 REV. E 02/2004
MODELS
CF5500-CMN
CF5500-CMP
FOR USE ONLY WITH DECORATIVE TYPE UNVENTED ROOM
HEATERS.
DO NOT BUILD A WOOD FIRE.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, AL-
TERATION, SERVICE OR MAINTENANCE CAN CAUSE IN-
JURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL.
FOR ASSISTANCE OR ADDITIONAL INFORMATION CON-
SULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE
GAS SUPPLIER.
WARNING: DO NOT BURN WOOD OR OTHER MATERIAL IN
THESE APPLIANCES.
CAREFULLY REVIEW THE INSTRUCTIONS SUPPLIED WITH
THE DECORATIVE TYPE UNVENTED ROOM HEATER FOR
THE MINIMUM FIREPLACE SIZE REQUIREMENT.
DO NOT INSTALL THE APPLIANCE IN THIS FIREBOX, UN-
LESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS
REQUIRED FOR THE INSTALLATIONS.
This is an unvented gas-fired heater. It uses air
(oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventila-
tion air must be provided. Refer to Combustion
and Ventilation Air Section, Page 3.
Due to high temperatures, the appliance should be located out
of traffic and away from furniture or draperies.
Do not place clothing or other materials on or near this appli-
ance.
IMPORTANT: READ AND UNDERSTAND THESE INSTRUCTIONS
COMPLETELY BEFORE INSTALLING YOUR UNVENTED ROOM
HEATERS.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.
STANDARD SERIES
CF6500-CMN
CF6500-CMP
1

Advertisement

Table of Contents
loading

Summary of Contents for Superior CF5500-CMN

  • Page 1 INSTALLATION INSTRUCTIONS STANDARD SERIES Unvented Decorative Gas Fireplaces P/N 904538 REV. E 02/2004 MODELS CF5500-CMN CF6500-CMN CF5500-CMP CF6500-CMP RETAIN THESE INSTRUCTIONS FOR USE ONLY WITH DECORATIVE TYPE UNVENTED ROOM HEATERS. FOR FUTURE REFERENCE DO NOT BUILD A WOOD FIRE. WARNING: IMPROPER INSTALLATION, ADJUSTMENT, AL- TERATION, SERVICE OR MAINTENANCE CAN CAUSE IN- JURY OR PROPERTY DAMAGE.
  • Page 2: Table Of Contents

    Input of the CF5500 Millivolt appliance is 24,000 Check the inventory list to be sure that you have TABLE OF CONTENTS BTU/hr maximum modulated to 19,000 BTU/hr all the necessary parts in usable condition. Also at the low flame setting for both natural and check for concealed damage.
  • Page 3: Codes

    • Children and adults should be alerted to the • These catalytic appliances are rated for The National Fuel Gas Code defines a con- hazards of high surface temperatures and should use at altitudes no greater than 5,500 feet. Do fined space as a space whose volume is less stay away to avoid burns or clothing ignition.
  • Page 4: Location Of Fireplace

    b. Vent room directly to the outdoors. Refer to 3. Add the BTU/hr of all the fuel burning appli- To ensure even heat distribution, it is best to National Fuel Gas Code, ANSI Z223.1 1992, ances in the space. position the heater centrally against the longest Section 5.3.
  • Page 5: Preinstallation

    Note: The following steps represent the normal 6" Clearance WARNING: DO NOT INSTALL THESE to Combustible sequence of installation. Each installation is APPLIANCES: Side Wall unique, however, and might require a different • WHERE CURTAINS, FURNITURE, sequence. CLOTHING OR OTHER FLAMMABLE Max.
  • Page 6: Framing Dimensions

    Note: Framing dimensions in Figures 4 - 9 are calculated for a nailing flange depth of " (13 mm). Outside Wall Outside Wall 19 " 15 " (495mm) (394mm) 37" (940mm) 41" (1041mm) CF6500 CF5500 Figure 4 Figure 7 Figure 10 Step 3.
  • Page 7: Electrical Wiring - Optional Blower . Page 7 Gas Pressure Check

    Gas Flex Line Kit, Model GFLV Standard Wiring Diagram If any of the original wire as supplied must be replaced, it " NPT x " must be replaced with Type AWM 105 C – 18 GA. wire. " x " Flare Flare Fitting Gas Valve Shut-Off Valve...
  • Page 8: Finished Wall Details

    Note: The header may rest on the top spacers but must not be notched to fit around them. OFF/ON Blower Wall Switch In order to install the appliance facing flush with To Fuse or Circuit Breaker the finished wall, position the framework to Black 120V Receptacle...
  • Page 9 Step 10. Checking the System – After the gas On propane models the last " (10mm) of the line is installed, logs are in place and the pilot generator should be engulfed in the pilot system is leak checked, run initial system flame.
  • Page 10: Flame Appearance

    Rear Burner Flames – The rear flames rising in The flame height and BTU input may be altered Thermopile front of center and rear logs should be yellow by rotating the flame control valve from low to high. and extend about 2 –...
  • Page 11: Optional Equipment

    The last " (10 mm) of the pilot generator The appliances covered in this manual are (thermopile) should be engaged with the pilot heater rated and produce a great deal of heat. flame. Decorative brass trim pieces and hoods may tarnish because of their proximity to the heater Replace logs if removed for pilot inspection.
  • Page 12 Screen Panel Kit Note: Instructions are also found on the pull- Wall Thermostat Kit out panel located in the lower control compart- ment of the appliance. An optional screen panel can be installed on the A wall thermostat kit is available for use with CF door.
  • Page 13: Cleaning And Servicing

    Maintenance Intentional misuse or deliberately fragmenting Alternatively, at least annually, the glass enclo- the material could be hazardous to health by sure panel should be removed and the inside of the firebox and the control compartments inhaling. CAUTION: DO NOT OPERATE THE APPLIANCE cleaned using a vacuum cleaner to remove WITH A BROKEN, DAMAGED OR MISSING dust.
  • Page 14: Accessories/Components

    ACCESSORIES AND COMPONENTS CO Sensor Kit CMSK Forced Air Kit FAB-1100 Gas Flex Line Kit GFLV SPK-5000 Brass Square BSK-5 Screen Panel Kits SPK-6000 Remote Control Kit Surround Kits BSK-6 Decorative VF5-PBH Wall Switch Kit Volcanic Stone Brass Hood Kit VF6-PBH VF5-BRLK 1-Piece Decorative...
  • Page 15: Appliance Specifications

    CF5500 SPECIFICATIONS CF6500 SPECIFICATIONS 37" " (940 mm) (1070 mm) " 15" " 20" (800 mm) (381 mm) (930 mm) (508 mm) 30" (762 mm) 34" (864 mm) 36" (914 mm) 40" (1016 mm) Front View Front View (CF5500) (CF6500) "...
  • Page 16: Troubleshooting Guide

    TROUBLESHOOTING THE CF MILLIVOLT GAS CONTROL SYSTEM Note: Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas supply inlet) is in the “ON” position. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A.
  • Page 17: Lighting Instructions

    LIGHTING INSTRUCTIONS – MILLIVOLT FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a pilot which must be lighted by hand. •...
  • Page 18: Replacement Parts List

    REPLACEMENT PARTS LIST — MILLIVOLT CF5500-CMN CF5500-CMP CF6500-CMN CF6500-CMP DESCRIPTION Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Gas Fireplace Assembly 128231 128232 128551 128552 Bar, Louver (Black) 024504 024504 104951 104951 Hood (Black), Clean Face 108951 108951 108971...
  • Page 19: Replacement Parts

    REPLACEMENT PARTS (SIT Valve Shown) NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.
  • Page 20: Warranty

    The duration of any implied warranty with respect to this Superior gas insert is limited to the duration of the foregoing warranty. Some states do not allow limitations on how long an implied warranty lasts, so the above may not apply to you.

This manual is also suitable for:

Cf6500-cmnCf5500-cmpCf6500-cmp