For use with an External Pump, see general guidelines below:
2 to 4 GPM circulation is recommended.
150W, 1.5A and lower pumps can be wired to the water heater PCB using the
Navien External Pump Wire (GXXX001319).
Check the Installation Manual for the specific water heater model for additional
pump wiring guidelines.
WARNING
An anti-scalding device must be installed in the system in order to limit the
DHW output temperature and prevent scalding. Set the temperature to 115-
120 ℉ .
Note
Install a spring check valve for vertical pipe runs. Do not use a swing check
valve with vertical piping.
Install either a spring check valve or a swing check valve for a horizontal run.
An outdoor sensor and a flow switch are supplied with the product.
Use 18 AWG wires for thermostat installation.
Install certified mixing valves and expansion tanks ONLY.
When using an external pump, connect the pump to the water heater PCB
directly using a Navien External Pump Cable (GXXX001319).
22
Configuring the Device