SECTION XII: WIRING DIAGRAM
CAUTION
OPEN ALL DISCONNECTS BEFORE
SERVICING THIS UNIT
THE 40,000 INPUT
FURNACE HAS ONLY
ONE ROLLOUT SWITCH
Y1
Y/Y2
W
R
G
C
RED/WHT
ROS
ROS
RED/BLK
RED
ORN/BLK
PS1
PS2
WHT
NO
C
C
NO
ORN
LS
RED/GRN
RED
PRP
FS
DS
NO
C
EAC
EAC
HUM
HUM
L
N
MOT
PF
G
1600/2000 CFM
MODELS ONLY
R
R
1,2,3,4
OR 5
C
G
G
MOT
C
Y1
Y1
Y/Y2
Y/Y2
W
W
TST
NOTES:
1. If any of the original wire as supplied with the furnace must be replaced,
it must
be replaced with wiring material having a temperature rating of
at least 221 degrees F (105 degrees C ).
2. Blower motor speed connections shown are typical, but may vary by
model and application.
NOTES:
1. Si l'un des fils d'origine fourni avec ce four doit être remplacé, il doit être
remplacé avec le fil ayant un degré de température d'au moins
221 degrés F (105 degrés C ).
2. Les connexions à grande vitesse du moteur du ventilateur indiqués sont
typiques, mais peuvent varier selon le modèle et par application.
FIGURE 40: Wiring Diagram
38
Wiring Diagram - 95% Single-Stage X Furnace
LO COOL
HI COOL
FURNACE CONTROL
10 11 12
7
8
9
4
5
6
4
3
2
1
1
2
3
2
1
IDM
GND
GV
115VAC
EAC
HUM
GND
IDM
HSI
XFMR
115V
COM
PRI
24V SEC
ROS
ROS
GV
GND
PS1
PS2
NO
C
C
NO
LS
BLU/WHT
RED-LOW
YEL-MED LO
GRY-MED
SEE NOTE 2
BLU-MED HI
BLK-HI
HEAT
1600/2000 CFM
EAC
MODELS ONLY
PF
L1
NO
C
DS
XFMR
LINE
HUM
WHT
WHT
BLU
BRN
GRY
WHT
GRY
WHT
HSI
S3
Diagnostic Fault Codes
Flashes
Fault Condition
Power Off or blown fuse
None
Slow Green
Normal Operation
Slow Amber
Normal Operation with call for heat
4 Amber
No G from thermostat
Steady on Red
Control Failure
1 Red
Flame present with gas off
2 Red
Pressure switch stuck closed
3 Red
Vent, intake, or termination problem
4 Red
Airflow problem OR open fuse
5 Red
Flame Rollout OR open fuse
6 Red
Repeated 3 Red
7 Red
Failed to light burners
8 Red
Loss of flame during call for heat
9 Red
Hot/Neutral reversed OR
poor ground/neutral
10 Red
Gas valve shorted "ON"
11 Red
Check blower motor/wiring
Fault Code Retrieval
Notice - Only a qualified service technician should use this feature.
Fault code retrieval functions will work only if there are no active thermostat signals.
To retrieve fault codes, push and release ERROR button on control board. The LED will flash the
last five error codes, beginning with the most recent. If there are no fault codes in memory, the LED
will give two green flashes. To clear the fault code memory, push and hold the ERROR button for
at least five seconds. The LED will give three green flashes when the memory has been cleared.
PRECAUTION
OUVREZ LES DISJONCTEURS AVANT
DE PROCEDER AVEC LE SERVICE
GND
Legend
5
C
4
DS -
Door switch
G
MOT
3
ROS -
Rollout switch
N
2
L
1
FS -
Flame sensor
TST -
Wall thermostat
BLK/WHT
PS1 -
Pressure switch
BLK
PS2 -
Condensate pressure switch
MOT -
Circulating motor
IDM -
Inducer motor
HSI -
Hot surface igniter
EAC -
115VAC
Electronic air cleaner
LS -
Limit switch
HUM -
Humidifier
XFMR -
Transformer
GV -
Gas valve
WHT
Legende
DS -
Commutateur de porte
ROS -
Commutateur de roulement
Transformeur
XFMR -
LS -
Commutateur de limite
HSI -
Ignition de surface chaud
Commutateur de pression
PS1 -
MOT -
Moteur soufflerie
IDM -
D'induct moteur
Soupape de gaz
GV -
HUM -
Humidificateur
PS2 -
Commutater de pression,
condensation
Thermostat
TST -
FS -
Capteur de flame
Filtre électrique
HUM -
1042427-UWD-A-0413
Johnson Controls Unitary Products

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents