(c. 42 Bar). These brazed joints may well be located in a public area and a weakness
leading to an explosion could be extremely dangerous.
The air curtain with its coil is manufactured in accordance with the Pressure Equipment
Directive (PED) and the installation must be carried out to a good standard of
workmanship. Remove the protective plastic film on top of the air curtain before starting
work and protect the top surface of the air curtain. Use a heat sink on the copper pipes
during brazing to reduce the transfer of heat to the inside of the air curtain where
sensitive components are located.

To gain access inside the Air Curtain

Please note: All the panels of the air curtain are covered in a protective plastic film
which should now be removed.
T9901105-1-1 UK
Slide open the access panels underneath the unit.
Remove the hexagon headed M6 screws using a
10mm nut driver.
Support the bottom access panel and hinge it open.