List of parameters and Factory stored programs
List of parameters and Factory Configuration program:
Parameter
Preflow
Start Current
Upslope
1
Set Current
Duty Cycle
Frequency (f)
Background
Downslope
Crater
Postflow
TIG SPOT WELDING (to previously enable with option 10 in Setup menu)
Parameter
Spot Current
TIG SPOT FIXED TIME (to previously enable with option 11 in Setup menu)
Parameter
Spot Time
1
It's possible change the maximum and mimimum selectable current with "Option 51" and "Option 52" in the Setup
Menu. If [Off] the set current are the "factory default", otherwise it is possible set another current.
English
Factory Configuration
0.3s
Lift TIG 2-step: 22A
Lift TIG 4-step: 30%
HF TIG 2-step: 30%
HF TIG 4-step: 30%
0.1s
50A
50%
50Hz
30%
0s
30%
5s
Features
Trigger = 2-step
No restart function enabled
Preflow time = 0s
Upslope time = 0s
Downslope time = 0s
Postflow time = 0s
Features
0 (manual trigger)
Selectable Value Range
0 - 5s (step 0.1s)
Not adjustable
5 - 200%
0 - 5s (step 0.1s)
5 - 160A (Stick)
5 - 160A (TIG))
10 - 90% (step 5%)
(f>300Hz Duty=50%)
0.1 - 10Hz (step 0.1Hz)
10 - 300Hz (step 1Hz)
300 - 500Hz (step 10Hz)
10 - 90% (step 1%)
0 - 20s (step 0.1s)
5 - 100% (step 1%)
0 - 30s (step 1s)
Selectable Value Range
5 - 160A
Selectable Value Range
0 - 5s (step 0.1s)
18
Displayed value
Current selected value (s)
Current selected value
(% of set current)
Current selected value (s)
Current selected value (A)
Current selected value (%)
Current selected value (Hz)
Current selected value
(% of set current)
Current selected value (s)
Current selected value
(% of set current)
Current selected value (s)
Displayed value
Current selected value (A)
Displayed value
Welding time (s)
English