Setup menu
The setup menu contains more parameters that are
hidden from the main control panel functionality.
To enter the Setup menu:
Push and hold "SEL" and "MODE" pushbuttons
Keep "SEL" + "MODE" pushed until the display shows
"
Then release the Pushbuttons
now is shown the option number "00"
01  99
Select the desired option: on the left display is shown
the option number
then press "SEL" to confirm
Now enable, disable or change the option value: on the
right display is shown the option status
Save the desired option by pressing the "SEL"
pushbutton
To exit the setup menu select the 00 option and keep
the SEL button pushed for 5 seconds until normal
operation is resumed.
English
+
"
List of menu options
Options
00
Exit point
01
2-step restart
02
4-step restart
10
Spot welding
11
Spot fixed time
20
Bi-Level
30
Foot Pedal
40
Arc start strenght
99
Reset to factory default
To change a setting push SEL, then rotate the encoder
(Output Current Knob) to modify the setting, and push
SEL again to confirm the new value.
15
Options Value
--
On/Off
On/Off
On/Off
On/Off
On/Off
On/Off
1/2/3/4
English