Heating Capacity
Input
Natural Gas Output
AFUE ¹
Available AC @ 0.5" ESP
Temperature Rise Range (°F)
Circulator Blower
Size (D x W)
Horsepower
Speed
Vent Diameter ²
No. of Burners
Minimum Filter Size
Electrical Data
Min. Circuit Ampacity ³
Max. Overcurrent Device (amps) ⁴
Ship Weight (lbs)
¹
For Use With Natural Gas Only. For altitudes + 4500' above sea level, see installation manual.
² DOE AFUE based upon Isolated Combustion System (ICS)
³ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in
accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
⁴ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use
fuses or HACR-type circuit breakers of the same size as noted.
Notes
• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
• Gas Service Connection ½" FPT
• Important: Size fuses and wires properly and make electrical connections in accordance with the National Electri-
cal Code and/or all existing local codes.
SS-GMVS80-U
GMVS80
GMVS80
0604BUA*
0805CUA*
60,000
80,000
48,000
64,000
80
80
1.5 - 4.0
2.0 - 5.0
20 - 50
35 - 65
10" x 8"
10" x 10"
3/4
3/4
Variable
Variable
4"
4"
1 Burner, 3 tubes
1 Burner, 4 tubes
(1) 20 x 25
(1) 16 x 25
(bottom) or
(side or bottom)
(2) 16 x 25 (side)
11.6
11.6
15
15
112
127
www.goodmanmfg.com