Settings And Adjustments; Default Dip Switch Settings - Hoshizaki KM-301BAJ Service Manual

Self-contained crescent cuber
Hide thumbs Also See for KM-301BAJ:
Table of Contents

Advertisement

C. Settings and Adjustments
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact your
Hoshizaki Service Center.

1. Default Dip Switch Settings

The dip switches are factory-adjusted to the following positions:
S1 Dip Switch No.
KM-231BAJ
KM-301BAJ
KM-301BWJ
S2 Dip Switch (Do Not Adjust)
Dip Switch No.
KM-231BAJ
KM-301BAJ
KM-301BWJ
Do not adjust the S2 dip switch. These must be left in the factory default position, or the
appliance will not operate properly.
1
2
3
4
OFF OFF OFF OFF ON ON OFF ON OFF ON
OFF OFF OFF OFF ON ON
OFF OFF OFF OFF ON
1
2
3
4
ON OFF OFF OFF OFF OFF
ON OFF OFF OFF OFF OFF
ON OFF OFF OFF OFF OFF
S1 Dip Switch
Harvest Time (1 & 2)
S2 Dip Switch (do not adjust)
NOTICE
5
6
7
8
ON OFF OFF ON
ON
ON OFF ON OFF
5
6
Freeze Timer (9 & 10)
Harvest Pump Time Duration (Harvest Assist) (7 & 8)
Pump-Out Frequency Control (5 & 6)
Pump-Out Time (3 & 4)
Slush Control (6)
Overfreeze Detection Control (5)
Harvest Completion Detection Control (4)
Refill Counter (3)
Harvest Promotion Control (2)
Pump-Out/Drain Selector (1)
35
9
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-231bajKm-301bwj

Table of Contents