Minimum Harvest Time (S2 Dip Switch 3); Harvest Completion Detection Control (S2 Dip Switch 4) - Hoshizaki KM-301BAJ Service Manual

Self-contained crescent cuber
Hide thumbs Also See for KM-301BAJ:
Table of Contents

Advertisement

9. Minimum Harvest Time (S2 dip switch 3)

Factory set for proper operation. Do not adjust. Adjustment outside the factory
default setting may result in damage to the appliance.
Do not adjust. This must be left in the factory default position or the unit will not operate
properly. The KM-231BAJ and KM-301BAJ/BWJ do not refill.

10. Harvest Completion Detection Control (S2 dip switch 4)

Factory set for proper operation. Do not adjust. Adjustment outside the factory
default setting may result in damage to the appliance.
It is deactivated on the KM-231BAJ and KM-301BAJ/BWJ.
When activated, this control determines whether ice remains on the evaporator at the
end of a harvest cycle and at the beginning of a freeze cycle. If ice drops and activates
the bin control switch in the last 10 seconds of a harvest cycle, the control determines
that ice still remains on the evaporator and extends the harvest cycle for 30 seconds.
If the bin control switch is activated at the beginning of a freeze cycle, the control
determines that ice still remains on the evaporator and starts a harvest cycle after the
minimum freeze cycle time has passed.
NOTICE
NOTICE
S2 Dip Switch Setting
No. 4
OFF
ON
39
Harvest Completion
Detection Control
Disabled
Enabled