C. Settings and Adjustments
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact your
Hoshizaki Service Center.
1. Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions for both the 2A7664-01
and 2A7664-02 control boards:
Model
1
KMD-860MAJ
OFF OFF OFF OFF OFF OFF ON OFF OFF OFF
KMD-860MWJ OFF OFF OFF OFF OFF OFF ON OFF OFF OFF
KMD-860MRJ
OFF OFF OFF OFF OFF OFF ON OFF OFF OFF
S5 Dip Switch (Do Not Adjust)
Model
All Models
S4 Dip Switch
2
3
4
5
1
2
3
4
OFF OFF OFF OFF ON
S4 Dip Switch
"J" Control Board
Freeze Timer (9 & 10)
Factory Use (8)
Harvest Pump Time (Harvest Assist) and Freeze-Time Correction (7)
(Do Not Adjust)
Harvest Pump Time Timer (Harvest Assist) (6)
Pump-Out Frequency Control (5)
Pump-Out Time (3 & 4)
Harvest Timer (1 & 2)
S5 Dip Switch (
"J" Control Board
NOTICE
6
7
8
9
5
Do Not Adjust)
Anti-Slush (5)
Minimum Harvest Time (4)
Refill Counter (2 and 3)
Float Switch Selector (1)
40