TriScroll 620 Series Vacuum Pump Warranty Products manufactured by Seller are warranted against defects in materials and workmanship for twelve (12) months from date of shipment thereof to Customer, and Seller’s liability under valid warranty claims is limited, at the option of Seller, to repair, to replace, or refund of an equitable portion of the purchase price of the Product.
Page 6
TriScroll 620 Series Vacuum Pump This page intentionally left blank.
TriScroll 620 Series Vacuum Pump Instructions for Use General Information Storage When transporting and storing the pump, the following This equipment is designed for use by professionals. The environmental requirements should not be exceeded: user should read this instruction manual and any other...
TriScroll 620 Series Vacuum Pump Installation Requirements Shutdown Procedure 1. Close the vacuum system isolation valve. This Do not install or use the pump in an environment prevents debris in pump from being transported into exposed to atmospheric agents (rain, snow, ice), dust, the vacuum system.
TriScroll 620 Series Vacuum Pump Installation CAUTION Although the pump can pump trace particulates normally found in the Safety atmosphere, it is not designed for pro- cess solids, chemicals, powders, sol- Do not remove or modify any safety or insulating vents, condensates, or other equipment from the pump.
TriScroll 620 Series Vacuum Pump Electrical Connections Wire the motor and electrical interlocks (if applicable) in accordance with local electrical codes and the relevant electrical component manufacturer’s instructions. Table 2 and Table 3 list the full load motor currents at various voltages.
TriScroll 620 Series Vacuum Pump Mechanical Connections Pump Exhaust A female 1/4" National Pipe Thread exhaust fitting is Pump Location located underneath the scroll module. This fitting swivels 360 degrees. Additionally, an NW25 male adapter with Locate the pump on a firm, level surface.
TriScroll 620 Series Vacuum Pump Optional Isolation Valve Overview The status of the VPI Valve is controlled by the TriScroll Scroll pumps return to atmospheric pressure quickly motor internal thermal switch and its electrical supply. when shut off, thus the installation of a fast acting,...
TriScroll 620 Series Vacuum Pump Gas Ballast Bearing Purge The gas ballast port (item 9 on Figure 3 on page 11) is The bearing purge port (item 6 on Figure 3 on page 11) is sealed on the TriScroll 620.
TriScroll 620 Series Vacuum Pump Troubleshooting Table 5 contains a list of possible problems, their probable causes, and corrective actions. Table 5 Troubleshooting Chart Problem Probable Cause Corrective Action Pump won’t start Circuit breaker open Close breaker. Identify cause of overload.
TriScroll 620 Series Vacuum Pump Maintenance General Information Agilent TriScroll 600 series pumps are designed to provide years of trouble-free service if maintenance procedures and intervals are observed. Bearing grease replenishment and tip seal replacement is recommended when pump base pressure has risen to an unacceptably high level for your application.
TriScroll 620 Series Vacuum Pump Factory Service Options Table 8 lists the factory-rebuild service and advance exchange of complete TriScroll 600 series pumps, as well as factory service options that Agilent offers. Table 8 Factory Service Options Factory Service Options...
Page 20
TriScroll 620 Series Vacuum Pump This page intentionally left blank.
Page 21
Please follow these instructions whenever one of our products needs to be returned. 1) Complete the attached Request for Return form and send it to Agilent Technologies (see below), taking particular care to identify all products that have pumped or been exposed to any toxic or hazardous materials.
Page 22
This page intentionally left blank. 4) HEALTH and SAFETY CERTIFICATION AGILENT TECHNOLOGIES CANNOT ACCEPT ANY PRODUCTS CONTAMINATED WITH BIOLOGICAL OR EXPLOSIVE HAZARDS, RADIOACTIVE MATERIAL, OR MERCURY AT ITS FACILITY. Call Agilent Technologies to discuss alternatives if this requirement presents a problem.
Page 23
Shipping Regulations (IATA, DOT, etc.) and carrier requirements. Customers receiving an Advance Exchange product agree to return the defective, rebuildable part to Agilent Technologies within 15 business days. Failure to do so, or returning a non-rebuildable part (crashed), will result in an invoice for the non-returned/non-rebuildable part.
Page 24
TriScroll 620 Series Vacuum Pump This page intentionally left blank.
Page 26
Service & Support North America India Southeast Asia Agilent Technologies Agilent Technologies India Pvt. Ltd. Agilent Technologies Sales Sdn Bhd Vacuum Products Division Vacuum Products Division Vacuum Products Division 121 Hartwell Avenue G01. Prime corporate Park, Unit 201, Level 2 uptown 2,...