Six Monthly Maintenance - Hussmann austral DD DELI-1 Series Installation Manual

Table of Contents

Advertisement

PRODUCT INSTALLATION MANUAL
2. Remove all price tickets and any foreign materials from the case.
3. Removal of all food products.
4. Clean glass or mirrored surfaces with a clean soft cloth and mild glass cleaner.
5. Wipe LED lights with a dry cloth.
6. Wipe down the exterior and interior of the case, paying particular attention to the perforations in the rear panels
and the air return grille with a clean soft cloth and mild soapy water.
7. Wipe over with clean dry cloth.
8. Remove the base trays, wash with mild soapy water and rinse.
9. Remove any foreign material from the base of the case.
10. Remove all food scrap.
11. Carefully flush the waste drain with a bucket of water and allow the base to drain.
12. Replace base trays, turn on lights and cleaning switch.
13. Allow the case to attain correct working temperature (approximately 30 minutes) and restock the shelves.

Six Monthly Maintenance

A thorough cleaning and maintenance check should be carried out on a six monthly basis by qualified and approved
refrigeration and electrical engineers. The following procedures should be undertaken as a minimum.
_________________________________________________________________________________________________________________________
Page 24
CAUTION
If case fan power is not isolated then staff should
wear hair nets and no jewellery or lose clothing.
The fan is protected by wire grill but the possibility
exists for items to be caught.
CAUTION
Cases should be electrically isolated
before carrying out any work that may
affect or expose electrical components.
DD13 2T SERVICE DELI
Hussmann

Advertisement

Table of Contents
loading

This manual is also suitable for:

Austral dd13

Table of Contents