Acer X1230S series Service Manual page 72

Hide thumbs Also See for X1230S series:
Table of Contents

Advertisement

3.
PC Alignment Procedure
OSD Default value:
Item
Cal R Offset
Cal G Offset
Cal B Offset
Cal R Gain
Cal G Gain
Cal B Gain
YPbPr R Offset
YPbPr B Offset
Procedure:
Gray Level:
1.
Connect power, D-sub, into projector.
2.
Change Timing and pattern of pattern generator:
3.
Timing: 1024*768 @60Hz (XGA)
4.
Pattern: As White-black pattern {A near white color (240,240,240) and a near black
color(16,16,16)}
5.
Light on projector
6.
Set user OSD values to default.
7.
Enter factory mode.
8.
Set Factory values to default.
9.
Press "Calibration RGB" to let the black level to just distinguish, and the light output
of white level to just max.
10. Check the 32 levels of gray. All steps must appear.
Value
127
127
127
127
127
127
127
127
White-black pattern
72