Scanning
Scanning the programmable memory channels
1. Press the [ V/M ( MW )] key to enter memory mode.
2. Turn the DIAL knob, or use the microphone keypad, to recall the upper or lower fre-
quency PMS memory channel (L1 or U1).
3. Press the [ # ] key on the MH-48A6JA Microphone.
"P1" appear on the right side of the display.
4. Press and hold [ UP ] or [ DWN ] on the microphone for over one second.
Programmable memory scanning will begin.
Note: To stop programmable memory scanning, press PTT on the microphone (this does
not cancel PMS mode).
To cancel PMS mode, when programmable memory scanning stops, press the [ # ]
key on the MH-48A6JA Microphone.
Band Edge Beeper
The FTM-3200DR will automatically "beep" when the receive band edge is encountered
during scanning (either in standard VFO scanning or during PMS operation). Additionally,
the band edge beep feature may be enabled to sound when the band edge frequency is
reached while tuning the VFO, using the DIAL knob.
The procedure to enable the Band-Edge Beeper (during manual tuning) is:
1. Press and hold in the [ MHz ( SETUP )] key for
one second, then rotate the DIAL knob to
select "BEP EDGE 4".
2. Press the [ MHz ( SETUP )] key, and then ro-
tate the DIAL knob to set this Menu item to
"ON".
3. Press and hold in the [ MHz ( SETUP )] key for
one second to save the new setting and exit
to normal operation.
20
VOL
SQL
REV
TXPO
D W
FTM-3200DR/DE Advance Manual
DIAL
D/A
M H z
V / M
SETUP
M W