INSTALLATION, START-UP & MAINTENANCE
INSTRUCTIONS

1.0 INTRODUCTION

Read all instructions before proceeding with the installation and start up.
This equipment must be installed in accordance with all relevant regulatory authority and industry requirements.
Only qualified, licensed technicians shall perform works on these units; failure to do so will result in warranty being
void.
Definitions:
 "Shall" indicates a mandatory requirement of this manual
 "Should" indicates a recommended requirement of this manual
Deviation from these instructions, may at the discretion of Brivis, void the warranty. As a result, the homeowner and
or installer may be charged a fee for non-product warranty related call outs. Also note that failure to comply with these
instructions may preclude Brivis from being able to service the appliance.
THE USER SHOULD RETAIN THIS MANUAL FOR FUTURE REFERENCE.

1.1 Brivis ICE R410a Inverter Range

The Brivis Inverter ICE series is a refrigerated cooling split only type air conditioner designed for connection to compatible
Brivis Ducted Gas Heaters. Brivis Inverter ICE utilises the heating system's ductwork and air circulation fan to distribute
cool, filtered refrigerated air.
ICE
Outdoor Model
DONSC10Z71
DONSC13Z71
DONSC15Z71
DONSC17Z71
Some heaters may require a transition to modify its starting collar (pop) size to suit the inlet pop size of the ICE
indoor coil. DO NOT REDUCE POP SIZES ON INDOOR COIL or HEATER.
Ensure minimum specified air quantity requirements passes through the ICE cooling coil at all times
Ductwork and fittings must be sized to handle the total cooling airflow through the system on either whole home or
zoned basis.

1.2 Safety / Warnings

The unit is designed to provide safe and reliable service when operating within design specifications. To avoid injury to
personnel and damage to equipment or property when operating the equipment, the following safe practices should be
observed as a minimum.
Check the unit weight to be sure the lifting equipment is adequate
Disconnect power to the unit before working on it
Do not remove access panels or doors until fans have completely stopped
Do not enter a fan cabinet while the fan is running
Protect materials when welding or flame cutting. Use suitable cloth to contain sparks. Have a fire extinguisher at
hand and ready for immediate use
Do not place articles on or against this appliance
Do not use or store flammable materials near this appliance
Do not spray aerosols in the vicinity of this appliance while it is in operation
Do not modify this appliance
Note: The communication cable installed between the indoor coil and outdoor unit shall be:
1.
Field supplied
2.
2-core shielded cable
3.
Earthed at the CDU end, refer to Fig.14
Failure to do so may prevent the correct operation of the unit
ICE
Nominal Cooling
Indoor Model
Capacity - kW
DINLU10Z7
DINLU13Z7
DINLU15Z7
DINXU17Z7
Table 1 – Brivis ICE Models and Heater Compatibility
Recommended Brivis
Gas Ducted Heater Model
10
Refer to latest Brivis Gas Ducted Heater
13
Specifications for Maximum Recommended
15
Add-On Cooling Capacity
17
3