Fig. 12 – Wiring Circuit for Brivis StarPro Series Heaters with Brivis ICE Add-On
StarPro model heaters can be configured for zoning and/or Add-On Refrigerative Air Conditioning. For more information
regarding connection to a StarPro unit please refer to the associated heater installer's manual.
Your zoning requirements may require a 'Brivis Network 516 module' (Brivis Part No. B023178), please refer to the
associated heater installer's manual.
Note: For Brivis ICE Add-On connection to a Brivis BX5 StarPro heater, a 'Brivis Network 516 module' (Brivis Part
No. B023178) must be fitted.
Fig. 13 – Wiring Circuit for Brivis Classic Series Heaters with Brivis ICE Add-On
HEATER
Relay
B063283
6
2
8
4
Red
7
3
1
0
Blue
White
*
For Brivis Classic 2PWN units the 'Fan speed terminal block' is inside the fan housing. The RED wire from the heater PCB
extends to the 'Fan speed terminal block' with a BROWN wire quick connect fitting. This BROWN wire shall be joined to the
RED wire supplied with ADD-ON relay, i.e. terminal 4.
Note: For Brivis ICE Add-On connection to a Brivis Classic heater (CC3, 2PWN, or BX3) an additional relay
'ACC LOOM ADD-ON RELAY CLASSIC' (Brivis Part No. B063283) must be fitted.
Contact Brivis Technical Support for information on superseded Brivis Heaters.
Using Brivis Networker
INDOOR UNIT ELECTRIC BOX
A1
A2
Using Brivis Programmable Thermostat
Heater
Control
Board
Red
*
Fan speed terminal block
Relay Wires
PCB Wires
Field Supplied Wires
NG-2A
Electronic Control Module
ZONE /
ZONE B
ZONE A
C Y
G W R
ADD-ON
Fn
M
Brivis Networker
240V
Active
Terminal
Block
R
Brown
W
To Add-On Cooling Unit
For connection refer to the installation manual
accompanying the Add-On cooling unit.
15
TSTAT
TW1 TW2
Programmable
Thermostat
Y
G
W
R

Advertisement