Regency Panorama PG33NG4-R Owners & Installation Manual page 20

Gas inbuilt
Table of Contents

Advertisement

installation
Option
H
Max.
A)
0.3m
B)
0.6m
C)
0.9m
D)
1.2m
E)
1.5m
20
Vertical Flueing with Three (3) 90
One 90
elbow = Two 45
elbows.
o
o
V
H + H1
V + V1
Min.
Max.
Min.
0.3m
0.9m
0.9m
0.6m
1.2m
1.5m
0.9m
1.5m
2.1m
1.2m
1.8m
2.7m
1.5m
2.1m
3.3m
Vertical Flueing with Three (3) 90
With these options, max. total
pipe length is 30 feet with min.
of 11 feet total vertical and
max. 7 feet total horizontal.
Please note min. 1 foot
between 90
elbows is
o
required.
Option
A)
0.6m
B)
0.9m
C)
1.2m
D)
1.5m
E)
1.8m
F)
2.1m
Elbows
o
Elbows
o
One 90
elbow = Two 45
elbows.
o
o
V
H + H1 V + V1
With these options, max. total
Min.
Max.
Min.
pipe length is 30 feet with min.
0.9m
1.2m
of 10 feet total vertical and
1.2m
1.8m
max. 8 feet total horizontal.
1.5m
2.1m
Please note min. 1 foot
between 90
1.8m
2.4m
required.
2.1m
2.7m
2.4m
3m
Regency PG33NG4-R Gas Inbuilt