Heat Mode Outdoor Air Temperature Characteristic - Panasonic CS-CZ25WKE Service Manual

Hide thumbs Also See for CS-CZ25WKE:
Table of Contents

Advertisement

20.2 Heat Mode Outdoor Air Temperature Characteristic

Condition
-
Indoor room temperature: 20°C Dry Bulb/ -°C Wet Bulb
-
Unit setting: Standard piping length, forced heating at 30°C, Hi fan
Compressor frequency: Rated for Heating operation
-
-
Piping length: 5m
-
Voltage: 230V
20.2.1
CS-CZ25WKE CU-CZ25WKE
3.70
3.20
2.70
2.20
1.70
1.20
2.60
2.40
2.20
2.00
1.80
1.60
1.40
1.20
36
32
28
24
20
16
-30
-25
-20
-30
-25
-20
-30
-25
-20
-15
-10
Outdoor Air Temperature (°C)
-15
-10
Outdoor Air Temperature (°C)
-15
-10
Outdoor Air Temperature (°C)
123
-5
0
5
-5
0
5
-5
0
5
10
10
10