19. Push the holdfast to the
left and lift up the
Evaporator.
Cross Flow Fan
Cross Flow Fan
"Precaution of Maintenance"
Removed all electrical parts before doing wet servicing.
Evaporator
20. Remove the Cross Flow Fan from the unit by
pulling it to the left and downward.
Figure 10
Figure 11
117
21. Fan Motor can be removed after
the removal of the Cross Flow Fan.
Reminder: To reinstall the Fan Motor,
adjust the Fan Motor connector to 60°
towards you before fixing Control Board
Reminder: To reinstall the Cross Flow Fan,
ensure the Cross Flow Fan is in line as
shown in figure 11.