Payne C Series Installation, Start-Up, Operating And Service And Maintenance Instructions page 15

Single-stage 4-way multipoise condensing gas furnace
Table of Contents

Advertisement

Remove plug from
collector box.
DO NOT DISCARD.
As Viewed in the Horizontal Right Orientation
NOTE: Remove knockout in
casing before re installing the
condensate trap.
Attach condensate
trap with screw to
collector box.
Install plug on
open port of
collector box
Unconverted Factory Configuration
Horizontal Right Trap Configuration
Fig. 10 − Horizontal Right Trap Configuration
(Appearance may vary)
15
If alternate vent position
is required, loosen clamp
on inlet of vent elbow.
Remove the screw that secures
the trap to the collector box and
remove trap.
Slide relief tube in stand offs
to adjust length.
Vent elbow shown in alternate
orientation. Tighten clamp on
inlet to vent elbow 15 lb. in.
Align trap over middle and
right hand port on collector box.
A11573