3Ware 9550SXU-12 User Manual page 239

Sas/sata raid software raid controllers
Table of Contents

Advertisement

www.3ware.com
Other Controller Settings
The Other Controller settings displays information about additional settings,
some of which can only be changed in the BIOS (3BM).
The Auto Rebuild policy determines how the controller
Auto Rebuild.
firmware will attempt to rebuild degraded units.
When Auto Rebuild is disabled, only spares will be used to automatically
rebuild degraded units. When Auto Rebuild is enabled, the firmware will
automatically select drives to use for rebuilding a degraded unit using the
following priority order.
Smallest usable spare.
Smallest usable unconfigured (available) drive.
Smallest usable failed drive.
For additional information, see "Setting the Auto Rebuild Policy" on page 91.
Auto-Carving.
Auto-carving can be enabled or disabled by selecting the
appropriate radio button.
When this feature is enabled, any unit that is over a specified size (known as
the carve size) will be broken down into multiple volumes of that size, plus a
remainder volume. The default carve size is 2048 GB (2 TB). For example,
using the default carve size, if the unit is 2.5 TB then it will contain two
volumes, with the first volume containing 2 TB and the second volume
containing 0.5 TB. If the unit is 5.0 TB then it will contain 3 volumes, with
the first two volumes containing 2 TB each and the last volume containing
1 TB. If a specific Boot Volume was also specified in 3BM, the first volume
will be the size specified for the Boot Volume, and then the carve size will be
applied to the remainder of the unit.
Sets a size for dividing up units into volumes when Auto-Carving
Carve Size.
is enabled. This setting can be between 1024 and 2048 GB.
Number of Drives Per Spin-up.
same time when the controller is powered up. (This setting only applies when
the feature is supported by the disk drives.)
Delay between Spin-ups.
that spin up at one time on this particular controller.
Export Unconfigured Disks.
individual drives attached to a 9000-series 3ware RAID controller that you
want to make available to the operating system, it is recommended that you
configure them as Single Disk units.
Number of Controller Phys.
controller. The 3ware 9690SA RAID controller has 8 phys.
Number of drives that will spin up at the
The delay time (in seconds) between drive groups
By default, this setting is No. If you have
The number of phy connections possible on the
Controller Settings page
227

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

9690sa3ware 9650se

Table of Contents