Polaris RZR PRO XP 2020 Service Manual page 51

Hide thumbs Also See for RZR PRO XP 2020:
Table of Contents

Advertisement

SPN
COMPONENT
Injector 1 (MAG)
651
Injector 2 (PTO)
652
677
Starter Solenoid Driver Circuit
731
Knock Sensor 1
Rear Differential Output (Turf)
746
AC Compressor Clutch Relay
876
Wheel Speed Sensor (Front Left)
905
Wheel Speed Sensor (Front Right)
906
Wheel Speed Sensor (Rear or
907
Rear Left)
9930583 R02 - 2020 RZR PRO XP / XP 4 Service Manual
© Copyright Polaris Industries Inc.
FMI
CONDITION
4
Voltage Below Normal, Or Shorted To Low Source
5
Current Below Normal Or Open Circuit
4
Voltage Below Normal / Shorted To Low Source / Driver Circuit
Grounded.
5
Current Below Normal / Open Circuit / Driver Circuit Open / Grounded
3
Voltage Above Normal, Or Shorted To High Source / Driver Circuit Short
to B+
4
Voltage Below Normal, Or Shorted To Low Source / Driver Circuit
Grounded
5
Current Below Normal Or Open Circuit / Driver Circuit Open / Grounded
3
Voltage Above Normal, Or Shorted To High Source
4
Voltage Below Normal, Or Shorted To Low Source
5
Current Below Normal Or Open Circuit
1
Data Valid But Below Normal Operational Range - Most Severe Level
2
Data Erratic, Intermittent Or Incorrect
3
Voltage Above Normal, Or Shorted To High Source
4
Voltage Below Normal, Or Shorted To Low Source
3
Driver Circuit Short to B+
4
Driver Circuit Grounded
5
Driver Circuit Open / Grounded
3
Voltage Above Normal, Or Shorted To High Source
4
Voltage Below Normal, Or Shorted To Low Source
5
Current Below Normal Or Open Circuit
2
Data Erratic, Intermittent Or Incorrect
3
Voltage Above Normal, Or Shorted To High Source
4
Voltage Below Normal, Or Shorted To Low Source
5
Current Below Normal Or Open Circuit
6
Current Above Normal Or Grounded Circuit
7
Mechanical System Not Responding Or Out Of Adjustment
8
Abnormal Frequency Or Pulse Width Or Period
10
Abnormal Rate Of Change
14
Special Instructions
20
Data Drifted High
21
Data Drifted Low
31
Condition Exists
2
Data Erratic, Intermittent Or Incorrect
3
Voltage Above Normal, Or Shorted To High Source
4
Voltage Below Normal, Or Shorted To Low Source
5
Current Below Normal Or Open Circuit
6
Current Above Normal Or Grounded Circuit
7
Mechanical System Not Responding Or Out Of Adjustment
8
Abnormal Frequency Or Pulse Width Or Period
10
Abnormal Rate Of Change
14
Special Instructions
20
Data Drifted High
21
Data Drifted Low
31
Condition Exists
2
Data Erratic, Intermittent Or Incorrect
3
Voltage Above Normal, Or Shorted To High Source
4
Voltage Below Normal, Or Shorted To Low Source
GENERAL INFORMATION
CODE
P1738
P1737
P1262
P0261
P0265
P1265
P0264
P0617
P0616
P0615
P0326
P0325
P0328
P0327
P1692
P1693
P1691
P0647
P0646
P0645
C1131
C1231
C1331
C1631
C1B31
C1731
C1431
C1831
C1531
C1931
C1A31
C0032
C1034
C1134
C1234
C1634
C1B34
C1734
C1334
C1834
C1434
C1934
C1A34
C1C34
C103D
C113D
C123D
1.45
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rzr pro xp 4 2020