LOW AMBIENT CONTROL
All RV absorption refrigerators, while similar, operate a
little differently than your home refrigerator. Dometic de-
signers and engineers have equipped your refrigerator
with an exclusive feature that allows for trouble-free op-
eration in low ambient temperature (like below 50°F) for
extended periods of time. Simply turn on the low ambi-
ent switch located beneath the top decoration panel that
houses the control panel (see figure 2, "D"). Once the
outdoor temperature is above 50°F, the low ambient
switch should be turned off.
ELECTRIC EQUIPMENT
HEATERS
The heat necessary for the operation of an absorption
cooling unit is supplied by an electric heater mounted in
a pocket of the boiler system.
This model is equipped with a series connected twin
heater.
To replace the heater proceed as follows:
1. Disconnect the wall plug, and the 12 volt wires.
2. Remove the protection cover see FIG. 1
3. Remove the power module cover see FIG. 1
4. Disconnect the heater leads.
5. With a pair of pliers unfold the lug holding the lid
of the boiler casing and open the lid.
6. Remove some insulation wool so that the heater
is accessible.
7. Turn and lift the heater out of its pocket.
8. Fit the new heater into the pocket.
9. Connect the leads and put on the power module
cover.
10. Reset the insulation and close the lid of the boiler.
11. Replace the protection cover.
FUSES
This model is equipped with 2 fuses, one for the refrig-
erator control system and one for the AC heater.
(See table below).
To replace fuse(s) proceed as follows.
1. Disconnect the wall plug, and the 12 volt wires.
2. Remove the power module cover. See FIG. 1.
3. Snap the fuse out of the fuse holder.
4. Fit a new fuse in to the fuse holder.
5. Replace the power module cover.
Control system
AC heater
3 Amp
5 Amp
MAINTENANCE & SERVICE
The user should be aware of service that must be
done on a regular schedule to keep the refrigerator
operating properly. The service should only be per-
formed by a qualified technician who is familiar with
refrigerators.
1. REFRIGERATOR REMOVAL
Before working on the refrigerator, make sure the AC
voltage and DC voltage leads are disconnected.
Loosen the screws anchoring the refrigerator to the
enclosure and slide the refrigerator out of the com-
partment.
When replacing the refrigerator make sure that the
sealing strips are properly positioned.
Replacement is the reverse of removal.
Refer to section INSTALLATION, page 4 to 8.
2. PERIODIC MAINTENANCE
To keep your Dometic refrigerator operating efficiently
and safely, periodic inspection and cleaning of sev-
eral components once or twice a year is recom-
mended.
A. It is important to keep the area at the back of the
refrigerator clean. Check the lower vent, upper vent
and area between these openings for any obstruc-
tions such as bird/insect nests, spider webs, etc.
Clean the coils on the back of the refrigerator. Use
a soft bristled brush to dust off the coils.
It is important to keep the refrigerator area free from
combustible material, gasoline and other flammable
vapors or liquids.