REFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATION.
NDR1272
Automatic Energy Selector
FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. Don't touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WARNING: Improper installation,
adjustment, alteration,service or
maintenance can cause injury or
property damage. Refer to this
manual. For assistance or additional
information consult a qualified
installer, service agency or the gas
supplier.
USA
Service Office
The Dometic Corporation
509 South Poplar Street
LaGrange, IN 46761
Phone: 219-463-4858
. .
Our goal.
your satisfaction.
Corporate Office
2320 Industrial Parkway Elkhart, IN 46515
For Service Center Assistance
Call: 800-544-4881
822707600
NEW DIMENSIONS
Contents:
installation
Operating instructions
Maintenance & Service
AVIS
Cet appareil doit &re repare
seulement par un reparateur
autorise. Modification de
I'appareil pourrait Qtre
extremement dangeruse, et
pourrait causer mal ou mort.
CANADA
Dometic Distribution Inc.
866 Langs Drive
Cambridge,Ontario
N3H 2N7 Canada
Phone: 519-653-4390
Page
4
8
12

Advertisement

loading

Summary of Contents for Dometic NDR1272

  • Page 1 Corporate Office 2320 Industrial Parkway Elkhart, IN 46515 For Service Center Assistance CANADA Service Office Call: 800-544-4881 Dometic Distribution Inc. The Dometic Corporation 866 Langs Drive 509 South Poplar Street Cambridge,Ontario LaGrange, IN 46761 N3H 2N7 Canada 822707600...
  • Page 2 Heaters Protection cover Flue baffle Cover, Reigniter 12 Volt Terminal block \ Power module cover FIG. 1 2 - WAY display panel. LEGEND 2-WAY AES Model 1. Main Power Button ON/OFF 2. AES/AUTO/GAS Mode Selector Button 3. Temperature Selector Button A.
  • Page 3 GAS CONNECTION INSTALLATION Hook-up to the gas supply line is accomplished at the GENERAL INSTRUCTION manual gas valve, which is furnished with a 3/8” SAE This appliance is designed for storage of foods (UNF 5/8” -18) male flare connection. All completed and storage of frozen foods and making ice.
  • Page 4 DC control is required to maintain the automatic energy The refrigerator must be installed in a substantial enclo- system). The connection is made to the positive (+) and sure and must be level. When installing the refrigerator negative (-) terminals of the terminal block on the back in the enclosure, all areas within the recess in which the of the refrigerator.
  • Page 5 Failure to follow the sequence in securing refrigerator in enclosure can cause leakage between the frame and cabinet. Any space between the counter, storage area or ceiling and top of the refrigerator greater den 1-1/2 inches should be blocked. The heat produced at the rear of the refrigerator will become trapped in this space, making the top of the refrigerator hot and reduce the efficiency of the refrigerator.
  • Page 6 CERTIFIED INSTALLATION METHODS OF INSTALLATION Certified installations require one roof vent and one The method of installation is shown in FIG. 9. It is lower side vent. essential that all maximum or minimum dimensions are For “Certified Vent System Kits” see page 15. strictly maintained as the performance of the refrigerator For further information contact your dealer or distributor.
  • Page 7 FIG. Overall Recess Refrigerator Dimensions Minimum Dimensions Model Height Width Depth Height Width Depth inch 59-31 /32 37-3/8 26-1 1 / 1 6 59-1/1 6 36-1/ 2 NDR 1272 1523 949.5 1500 This method of installation and these clearances will give you adequate space for service and proper installation. OPERATING OPERATION INSTRUCTIONS...
  • Page 8 2 - WAY display panel C O L D 1 COLDEST THERMOSTAT START UP INSTRUCTIONS The thermostat on the refrigerator controls both the gas A continuous 12 volt DC supply must be available for and electric operation, thereby eliminating the necessity the electronic control to function.
  • Page 9 display panel 2 - WAY C O L D 1 COLDEST O F F CHECK DESCRIPTION OF OPERATING LIMP MODE OF OPERATION MODES This control system contains a feature where it will AES/AUTO MODE continue to operate the cooling system in the event of a failure of a major operating component.
  • Page 10 DEFROSTING HOW TO USE THE REFRIGERATOR Shut off the refrigerator by pressing the main power ON/OFF button to the UP (OFF) position. FOOD STORAGE COMPARTMENT Empty the refrigerator, leaving the drip tray under the The food storage compartment is completely closed and finned evaporator, and the cabinet and freezer doors unventilated, which is necessary to maintain the re- open.
  • Page 11 Fit the new heater into the pocket. PERIODIC MAINTENANCE Connect the leads and put on the power module To keep your Dometic refrigerator operating efficient- cover. ly and safely, periodic inspection and cleaning of 10. Reset the insulation and close the lid of the boiler.
  • Page 12 Check all connections in the LP gas system (at the back of the refrigerator) for gas leaks. The LP gas DO NOT use a wire or pin when cleaning the burner supply must be turned on. Apply a non-corrosive jet as damage can occur to the precision opening. bubble solution to all LP gas connections.
  • Page 13 A minimum of 9.6 volt DC supply present for the INSTRUCTION FOR MOUNTING refrigerator control system. THE DOOR PANEL The thermostat can not be moved from MID position The refrigerator is normally delivered without door to the desired setting. The display module has be- panels.
  • Page 14 CERTIFIED VENT SYSTEM KITS Refr. Model Components Part No. NDR 1272 Roof Base 3103633.xxx * Roof Cover 3103634.xxx * Lower Side Vent 3103847.004 3105101.000 Power Vent Asm. 3104131.002 ** * Fill in “xxx” with color code numbers. For color codes, contact your supplier. ** Alternate instructions forwarded with the Vent Kit.
  • Page 15 SPARE PARTS The following list is a list of commonly used parts which should be available, if required, from your Dometic Service Center. Part No. Description 17 37 58-03/8 Heater, 210W, 120V 95 50 01 -67/2 Burner pipe, cpl. 200 74 1 9-33/2 Jet, No.