Basic Controls Usage; Scrolling Marquee Display - Carrier AquaSnap 30RAP011-060 Controls, Start-Up, Operation, Service, And Troubleshooting

Air-cooled chillers
Table of Contents

Advertisement

Configuration mode, Option sub-mode, would be written as Con-
figuration OPT2LLCS.
This path name will show the user how to navigate through the lo-
cal display to reach the desired configuration. The user would
scroll through the modes and sub-modes using the
keys. The arrow symbol in the path name represents pressing
to move into the next level of the menu structure.
ENTER
When a value is included as part of the path name, it will be shown
at the end of the path name after an equals sign. If the value rep-
resents a configuration setting, an explanation will be shown in pa-
rentheses after the value. As an example, Configura-
tionOPT2LLCS = 1 (Automatic).
Pressing the
and
ESCAPE
scroll an expanded text description of the point name or value
across the display. The expanded description is shown in the local
display tables but will not be shown with the path names in text.
The CCN (Carrier Comfort Network
enced in the local display tables for users configuring the unit with
CCN software instead of the local display. The CCN tables are lo-
cated in Appendix B of the manual.
Table 1 — Unit Sizes
UNIT
30RAP010
30RAP011
30RAP015
30RAP016
30RAP018
30RAP020
30RAP025
30RAP030
30RAP035
30RAP040
30RAP045
30RAP050
30RAP055
30RAP060
30RAP070
30RAP080
30RAP090
30RAP100
30RAP115
30RAP130
30RAP150

Basic Controls Usage

SCROLLING MARQUEE DISPLAY

The scrolling marquee display is the standard interface display to
the ComfortLink Control System for 30RAP units. The display
has up and down arrow keys, an
key. These keys are used to navigate through the different levels of
the display structure. Press the
erating level is displayed to move through the top 11 mode levels
indicated by LEDs (light-emitting diodes) on the left side of the
display. See Fig. 1 and Table 2.
and
keys simultaneously will
ENTER
) point names are also refer-
®
NOMINAL CAPACITY (TONS)
10
10
14
14
16
19
24
28
34
39
43
48
52
56
69
77
85
99
112
126
140
key, and an
ENTER
ESCAPE
ESCAPE
key until the highest op-
MODE
Run Status
Service Test
Temperature
Pressures
Setpoints
Alarm Status
Inputs
Outputs
ESCAPE
Configuration
Time Clock
Operating Modes
Alarms
Fig. 1 — Scrolling Marquee Display
Once within a mode or sub-mode, pressing the
ESCAPE
keys simultaneously will put the scrolling marquee
display into expanded text mode where the full meaning of all
sub-modes and items and their values can be displayed for the cur-
rent selection. Press the
the scrolling marquee display to its default menu of rotating dis-
play items (those items in Run Status  VIEW). In addition, the
password will be disabled, requiring that it be entered again before
changes can be made to password protected items. Press the
key to exit out of the expanded text mode.
ESCAPE
NOTE: When the Language Selection (Configuration 
DISP  LANG), variable is changed, all appropriate display ex-
pansions will immediately change to the new language. No pow-
er-off or control reset is required when reconfiguring languages.
When a specific item is located, the item name alternates with the
value. Press the
ENTER
will be displayed. Press
to flash indicating that the value can be changed. Use the up and
down arrow keys to change the value, and confirm the value by
pressing the
key.
ENTER
Changing item values or testing outputs is accomplished in the
same manner. Locate and display the desired item. Press
so that the item value flashes. Use the arrow keys to
ENTER
change the value or state and press the
Press the
key to return to the next higher level of struc-
ESCAPE
ture. Repeat the process as required for other items.
Items in the Configuration and Service Test modes are password
protected. The words "PASS" and "WORD" will alternate on the
display when required. The default password is 1111. Press
and the 1111 password will be displayed. Press
ENTER
again and the first digit will begin to flash. Use the ar-
ENTER
row keys to change the number and press
digit. Continue with the remaining digits of the password. The
password can only be changed through CCN operator interface
software such as ComfortWORKS™, ComfortVIEW™, and Ser-
vice Tool.
Configuration value cannot be changed while the unit is enabled.
Remote Control-Off-Enable must be in the Off position in order to
change any configuration mode.
See Table 2 and Appendix A for further details. See Table 3 for a
description of operating modes.
4
ENTER
ENTER
and
keys to return
ENTER
ESCAPE
key at a changeable item and the value
again and the value will begin
ENTER
key to accept it.
ENTER