2.2
Removal and reinstallation of the operation
panel or the front covers
Removal and reinstallation of the operation panel
• Loosen the two screws on the operation panel.
(These screws cannot be removed.)
To reinstall the operation panel, align its connector on the back with the PU connector of the inverter, and insert the operation
panel. After confirming that the operation panel is fit securely, tighten the screws. (Tightening torque: 0.40 to 0.45 N·m)
Removal of the lower front cover
(a)
(a)
When the mounting screws are removed, the lower front cover can be removed. (The number of the mounting screws differs by
the capacity.)
(b)
With the lower front cover removed, the main circuit terminals can be wired.