Removal and reinstallation of the front cover
2.2
Removal and reinstallation of the front cover
Removal of the accessory cover and installation of the operation panel
• Loosen the two fixing screws on the accessory cover.
(These screws cannot be removed.)
• To install the inverter operation panel, align its connector on the back with the PU connector of the inverter, and insert the
operation panel. After confirming that the operation panel is fit securely, tighten the screws. (Tightening torque: 0.40 to 0.45
Nm)
Removal of the front cover (lower side)
(a)
(a)
Remove the mounting screws to remove the front cover (lower side).
(b)
With the front cover (lower side) removed, wiring of the main circuit terminals can be performed.
18
INSTALLATION AND WIRING
• Push the upper edge of the accessory cover and pull the
accessory cover to remove.