10-1. Installation Diagram of Indoor and Outdoor Units
Batteries
3
2
Wireless remote control
• Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (-) positions.

10. INSTALLATION PROCEDURE

6
Flat head
4
Remote control holder
wood screw
Vinyl tape
Apply after carrying
out a drainage test.
Before installing the wireless remote controller
2 Wireless remote controller
Hook
Installation
1
plate
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
Do not allow the drain hose to get slack.
Shield pipe
Make sure to run the drain hose sloped
downward.
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Saddle
Insulate the refrigerant pipes separately
with insulation, not together.
Extension drain hose
(Not available, provided
by installer)
- 45 -
FILE NO. SVM-17030
For the rear left and left piping
Wall
Cut the piping
hole sloped
slightly.
Right
Rear
right
Left
Bottom
Rear
right
left
Bottom left
6 mm thick heat resisting
polyethylene foam