Specifications Of Electrical Parts - Toshiba RAS-10BKV-E1 Service Manual

Table of Contents

Advertisement

6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit
No.
Parts name
1
Fan motor (for indoor)
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
4
Louver motor
6-2. Outdoor Unit
No.
1
Compressor
2
Fan Motor
3
Pulse Modulating Valve (PMV) coil
4
4-Way Valve coil
5
Suction temp. sensor
6
Discharge temp. sensor
7
Outside air temp. sensor
8
Heat Exchanger temp. sensor
9
Terminal block
Parts name
(TS sensor)
(TD sensor)
(TO sensor)
(TE sensor)
(5 poles)
Type
SJM-240-25
AC 220~240V, 25W
( - )
10kΩ at 25°C
( - )
10kΩ at 25°C
Output (Rated) 4 phase, DC12V
24BYJ48A-080
Type name
ASK89D53UEZ
3-Phases (6-Poles) ; 682W
ICF-140-43-4R
DC 140-340V, 43W
PQ-M10012-000313
DC 12V
DXQ-939
AC 220-240V
10kΩ at 25°C
(Inverter attached)
62kΩ at 20°C
(Inverter attached)
(Inverter attached)
10kΩ at 25°C
(Inverter attached)
10kΩ at 25°C
JXO-5B
AC 250V, 20A
- 18 -