4
|
Operation

4.4 Space heating control

4.4.1 Determining which temperature control you are using

User reference guide
14
To turn ON or OFF the room temperature control
1 Go to the room temperature home page (Room).
2 Press
.
To turn ON or OFF the leaving water temperature (main + additional) control
1 Go to one of the following the home pages:
▪ Main leaving water temperature home page (LWT main)
▪ Additional leaving water temperature home page (LWT add)
2 Press
.
To turn ON or OFF the domestic hot water control
1 Go to the DHW tank temperature home page (Tank).
2 Press
.
To turn ON or OFF the instant domestic hot water control
1 Go to the instant DHW temperature home page (DHW).
2 Press
.
NOTICE
Room frost protection. Even if you turn OFF the leaving water temperature (main +
additional) control via the home pages (LWT
protection –if enabled– will remain active.
To determine which temperature control you are using (method 1)
Check the installer settings table filled in by the installer.
To determine which temperature control you are using (method 2)
If you have 2  user interfaces, perform the following procedure on the user
interface at the indoor unit.
Prerequisite: You switched the permission level to Advanced end user.
1 Press
multiple times to switch between home pages, and check if the
additional leaving water temperature home page (LWT add) is available:
If ...
Available
NOT available
main + LWT
add), room frost
Then you have...
A main zone and an additional zone
Only a main zone
CHYHBH05+08AF + EHYKOMB33AA