Download Print this page

Meter Readings - Fluke i800 Instruction Sheet

Ac/dc current clamp

Advertisement

Distributor of Fluke Electronics: Excellent Integrated System Limited
Datasheet of I800 - CURRENT CLAMP PROBE AC
Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com
Wire size and the position of the wire within the probe
jaws does not affect measurement accuracy.
4.
Multimeter readings displayed in milliamps (mA) can be
read directly as amperes of conductor current. Readings
displayed in amperes (A) must be multiplied times 1000
to obtain the amperes of conductor current.
Single
Current Carrying
Conductor

Meter Readings

When the Clamp is connected to a compatible current meter and
clamped around a single current-carrying conductor, the meter
reading will be one 1000th of the actual current in the conductor.
For example, a 5 A input current will be transformed into a 5 mA
output current (see Figure 1). When measuring current in an ac
line cord, the jaws should be clamped around only one conductor
(the black or hot wire in a three wire cord). If the jaws are
clamped around both current carrying conductors, the currents
will cancel and produce a zero reading. If the probe is clamped
around two wires carrying current in the same direction, the sum
will be read. Reversing one of the wires causes the difference to
320 A
Tactile
Barrier
Figure 1. Current Measurement
Note
HOLD
mA
MIN MAX
RANGE
mA
CAT
CAT
eyd001f.eps

Advertisement