ABB Sense7 Series Product Manual

ABB Sense7 Series Product Manual

Non-contact coded safety switch
Hide thumbs Also See for Sense7 Series:

Advertisement

Quick Links

SA F E T Y PR OD U CTS
Non-contact coded safety switch
Sense7-series
Product Manual
----C
2TLC172249M0201, REV. C
ORIGINAL INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for ABB Sense7 Series

  • Page 1 — SA F E T Y PR OD U CTS Non-contact coded safety switch Sense7-series Product Manual ----C 2TLC172249M0201, REV. C ORIGINAL INSTRUCTIONS...
  • Page 2 Read and understand this document Please read and understand this document before using the products. Please consult your ABB Motor Start- ing & Safety representative if you have any questions or comments. Suitability for use ABB Electrification Sweden AB shall not be responsible for conformity with any standards, codes, or regula- tions that apply to the combination of products in the customer’s application or use of the product.
  • Page 3: Table Of Contents

    Table of Contents 1 Introduction ...................................4 Scope....................................... 4 Audience ......................................4 Prerequisites ....................................4 Special notes ....................................4 2 Overview ..................................5 General description ..................................5 Safety regulations ..................................5 Function description ..................................5 3 Connections ................................... 6 4 Installation and maintenance ............................8 Installation and maintenance ..............................
  • Page 4: Introduction

    This document is intended for authorized personnel. Prerequisites It is assumed that the reader of this document has knowledge of the following: • Basic knowledge of ABB Electrification Sweden AB products. • Knowledge of safety devices. • Knowledge of machine safety.
  • Page 5: Overview

    Overview General description The coded non-contact switches Sense7 are designed to provide position interlock detection for moving guards. They are designed to fit the leading edge of sliding, hinged, or lift off machine guards. The actuator is fitted to the moving part of the guard, and is aligned to the switch, placed on the frame of the guard. Its design makes it advantageous to operate in environments that require the highest level of safety.
  • Page 6: Connections

    Connections See Chapter Installation and Maintenance for more information regarding installation. Connections For all ABB switches the NC circuits are closed when the guard is closed and the actuator present. BLUE (24VDC) (0VDC) BLACK (IN) & POWER Circuit 1 WHITE (OUT) YELLOW (IN) &...
  • Page 7 Pin configurations Connection colours: (Important: The NC1 and NC2 Outputs are polarity sensitive). Quick Connect (QC) Flying Lead Circuit Output Types M12 8 way Colors (Actuator present) Solid State Male Plug (Pin view from switch) Orange Auxiliary (NO) 200mA Max. 24Vdc Brown Auxiliary (NO) Yellow...
  • Page 8: Installation And Maintenance

    Installation and maintenance Installation and maintenance The installation of all ABB Electrification Sweden AB interlock switches must be done in accordance with a risk assessment for the individual application. Installation must only be carried out by compe- tent personnel and in accordance with these instructions.
  • Page 9: Minimum Safety Distance

    Caution! ABB Electrification Sweden AB will not accept responsibility for failure of the switch functions if the installation and maintenance requirements shown in this sheet are not implemented. These require- ments form part of the product warranty. Minimum safety distance When using interlocking guards without guard locking to safeguard a hazard zone, the minimum allowed safety distance between the guarded opening and the hazardous machine must be calculated.
  • Page 10: Application Examples

    Application examples For the latest connection diagrams, please see our web page: https://library.abb.com/r?cid=9AAC170124&dk=connection%20diagram Solution for two NC-contacts Note: The PL should be calculated using ISO/TR 24119 and EN ISO 13849-1/2 2TLC172249M0201, REV. C 2021-10-12...
  • Page 11: Solution For One Nc-Contact And One No-Contact

    Solution for one NC-contact and one NO-contact Note: The PL should be calculated using ISO/TR 24119 and EN ISO 13849-1/2 2TLC172249M0201, REV. C 2021-10-12...
  • Page 12: Model Overview

    Model overview Type Product ID Description Sense7 2TLA050056R4100* 2 m cable, 2NC/1NO, LED Sense7 2TLA050056R5100* 5 m cable, 2NC/1NO, LED Sense7 2TLA050056R6100* 10 m cable, 2NC/1NO, LED Sense7 2TLA050056R2100* 250 mm cable with M12, 2NC/1NO, LED Sense7Z 2TLA050056R4120 2 m cable, 2NC/1NO, LED, Stainless Steel Sense7Z 2TLA050056R5120 5 m cable, 2NC/1NO, LED, Stainless Steel...
  • Page 13: Technical Data

    Technical data Manufacturer ABB Electrification Sweden AB Address SE-721 61 Västerås Sweden Electrical characteristics Minimum switched current 10VDC 1mA Dielectric withstand 250 VAC Safety channel 1-NC 24VDC 0.2 A max. rating Safety channel 2-NC 24VDC 0.2 A max. rating Safety channel 3-NO 24VDC 0.2 A max.
  • Page 14 Safety-related characteristic data and Conformity Conformity European Machinery Directive 2006/42/EC EN ISO 12100:2010, EN ISO 14119:2013, EN ISO 13849-1:2015, EN 60947-5- 3:2013 EN ISO 13849-1 Up to PLe Category 4 (if both channels are used with a PLe control device) EN 62061 Up to SIL3 depending on system architecture Safety data...
  • Page 15: Ec Declaration Of Conformity

    EC Declaration of conformity ABB Electrification Sweden AB SE-721 61 Västerås, Sweden https://new.abb.com/low-voltage/ 2TLC172249M0201, REV. C 2021-10-12...

Table of Contents