G32A-A40-VD/G32A-A60-VD/G32A-A430-VD
The G32A Power Device Cartridge is mounted and secured with screws to the G3PA Unit.
Extraction
Follow the procedures below to dismount the G32A-A Power De-
vice Cartridge from the G3PA.
1. Switch off the power.
2. Remove the terminal cover.
3. Loosen the two centered screws on the sides to dismount the
cartridge. The screws are connected to terminals 1 and 2.
Loosen
4. Loosen the screws on both the corners.
Loosen
5. Hold the indented part of both the corners to dismount the
cartridge.
Mounting
Loosen
Loosen
1. Apply silicone grease to the entire surface of the heat radiator.
Apply silicone grease here.
2. Make sure that there is no dust or pieces of wire on the
radiator of the G32A-A or the G3PA.
3. Insert the cartridge into the opening of the G3PA so that side A
and side B are even.
4. Tighten the screws on both the corners with a tightening
torque of 0.59 to 0.78 N m.
5. Tighten the screws on both the sides with a tightening torque
of 0.59 to 0.78 N m.
6. Attach the terminal cover.
7. Switch on the power and check the G3PA to be sure it works
properly.
G3PA-(VD)
Side A
Side B
143