There are two parts in this test item.
(1) TX Power Scaling Factor
1.
Select Band.
2.
Click [READ].
3.
Select middle channel (37 for GSM etc.),
4.
Select power level (5 for GSM, 0 for DCS+PCS).
5.
Configure test set for TX power.
6.
Click [APPLY] for AFRCN.
7.
Click [APPLY] for scaling factor.
8.
Read power level on test set.
9.
Adjust scaling factor to nominal power.
10. Copy scaling factor value to box "5" in the relevant table.
11. Add scaling factor value to box "0" to "4" in table.
12. Repeat (3) to (9) for DCS, PCS.
13. Copy scaling factor value to box "0" in the relevant table.
14. Copy scaling factor to correct location in table.
15. Click "WRITE" (response: NVRAM WRITE ).