• Limiting reach
The detection zone can be optimised to suit requirements.
– By adjusting the lens. (Fig� 5�8 / 5�10)
– By using the half-round clip-on shroud. (Fig� 5�11)
Note:
To limit reach, the sensor module must be detached from the load module.
• To activate the required reach, undo the screws or completely remove them.
• Move lens into required zone.
• The half-round clip-on shroud provided can be used for masking out any number
of lens segments to shorten reach as required.
• Afterwards, fix the lens in place with the screws.
Detection zone/reach
IS 3360 (Fig� 5�6)
IS 3360 MX (Fig� 5�7)
Mounting height
14 m
9 m
6 m
2.8 m
IS 345 (Fig� 5�8
IS 345 MX (Fig� 5�9)
Mounting height
14 m
10 m
8 m
6 m
4 m
Reach (tangential)
10 m
14 m
16 m
18 m
Reach (tangential)
30 m × 4
25 m × 4
20 m × 4
15 m × 4
10 m × 4