Optionally, all function settings can be made via the RC5, RC8 remote controls
as well as the Smart Remote. (➔ "7� Accessories")
Package contents for concealed installation (Fig� 3�1)
Package contents for surface-mounted installation (Fig� 3�2)
Product components (Fig� 3�3)
A Load module, power supply lead, surface-mounted
B Load module, power supply lead, concealed installation
C Designer trim, round or square
D Sensor module
E Half-round clip-on shroud
Product dimensions
Surface-mounted / concealed (Fig� 3�4)
IS 3360 IS, IS 3360 MX, IS 345
Surface-mounted / concealed (Fig� 3�5)
IS 345 MX
Surface-mounted / wall-mounted (Fig� 3�6)
IS 3180
4� Electrical installation
The mounting location should be at least 50 cm away from other lights because
heat radiated from these may activate the system.
An optional corner wall mount (product no. 648015 black or 035174 white) is
available for mounting the IS 3180.
The supply lead consist of three wires:
L
= phase conductor (usually black, brown or grey)
N
= neutral conductor (usually blue)
PE
= protective-earth conductor (green/yellow)
S1 / S2 = Input and output of the floating relay
Note on manual override function (Fig� 4�1):
A power switch for switching ON and OFF can be installed in the mains supply lead.
This is a prerequisite for the manual override function (➔ "6� Function")
If the rubber seal is damaged, the cable entry openings must be sealed with an M16
or M20 (at least IP 54) double seal cable gland.