RF Description and Troubleshooting
FTM setup for TX troubleshooting
Put PWB on the module jig. Use the following steps to configure FTM for RF
troubleshooting.
1. Set SW1 to "FTM mode" in Module Jig.
2. Connect RF connector to a spectrum with a CA-89RS RF Test Cable.
3. Connect 6066 mobile terminal to a PC via Module Jig, and connect power
supply to Module Jig.
4. Open RF Tools software in 6066 CCS Level 3 service software.
5. The FTM dialog box appears.
6. Set "Connect Phone".
7. Set "Set FTM".
8. Set "Set Band" to "CDMA800".
9. Set "Set Channel " to Channel "384".
10. Set "Set Pa Range R1" to "on".
11. Set "Set TX waveform" to "CDMA".
12. Set "Set TX on/off" to "on".
13. Set "Set TX AGC" to "100".
Page 6
© 2006 Nokia Corporation
Figure 4: FTM dialog box
Company Confidential
Issue 1 11/2006