TX DC Test Points

Test Point
Description
1
PA_ON
2
PA_R1
3
LOCK_DET
4
TX_AGC
5
Tx IQ in
6
DAC_REF
7
VREG_MSMP
8
VREG_RFTX
Table 1 shows the Tx DC Test Points shown in Figure 5.
Issue 1 11/2006
© 2006 Nokia Corporation
Figure 5: Tx DC test point
Value
2.95V for PA turning on, 0 V for turning off
2.01V for high gain mode,1.46V for low gain
mode
2.96V for Lock, 0 V for unlock
1.85V for 5dBm, 2.04V for 15dBm, 2.28V for
25dBm.
0.84 V With oscilloscope: 500 mV p-p
1.82V
2.96V
2.65V