System Operation Check List; Transport Functions - Sony APR-5001 Series Operation And Maintenance Manual

Analog tape recorder
Hide thumbs Also See for APR-5001 Series:
Table of Contents

Advertisement

OUTPUT
AUDIO OUT
+ 4 dBu
,
low impedance
,
balanced
( 600 ohm load permissible )
TIME CODE OUT
6 dBu
±
3 dB , low
impedance
,
balanced
REMOTE STATUS
TTL
compatible
,
2 - 5 V is OFF
(
HIGH )
,
0
- 1 V is
ON
(
LOW
)
.
Current
sink capability :
12 mA at 0.4 V
, 24 mA at 0.5 V
z
o
s
I
2
CO
z
Unbalanced
,
+
4 dBu nominal ( 0 dBu
=
0.778 VRMS
)
CALIBRATION OUT
HEADPHONES
8
ohm load , or greater , binaural
EXTERNAL NOISE
REDUCTION
RELAY
SUPPLY
24 volts
maximum
.
Maximum saturation current : 100 mA
at 24V
TAPE TACHOMETER
480 Hz at 30
ips ,
240 Hz at 15
ips
REMOTE POWER SUPPLY
Regulated
+
5 VDC
0.5 amps
maximum
Table 3 - 10 . Output Signals
3.8 SYSTEM OPERATION CHECK LIST
3.8
.
1 Transport Functions
Connect
the APR - 5000 to
an
appropriate
AC power source
.
It
is recommended that the following functions should
be checked when the machine is first powered on
.
These functions should also be checked whenever per
-
forming maintenance
or
repair
on
the
APR - 5000
.
The
check procedure described here is designed to be
checked from the
APR - 5000
itself
,
but can be applied
to
operation with
a remote
control
. It
is recommend -
ed that if
a
problem arises when executing the pro -
cedure with the remote control connected that power
be turned off and the remote control removed to
check the
APR
-
5000
alone
.
STEP 1
Turn
the power switch
on and check
the
following :
STEP 2
CHECKOUT PLACE
CHECKOUT ITEM
The solenoid engages and the brake is released
.
Reel Motors
3 - 10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Apr-5002 seriesApr-5003v series