Folder Open/Close Trouble - LG MG210 Service Manual

Table of Contents

Advertisement

4.13 FOLDER Open/Close Trouble

Block Diagram
HALL EFFECT S/W
Folder Operation
• There is a magnet to detect the Flip status, opened or closed.
• If a magnet is close to the hall-effect switch(U301), the voltage at pin 2 of U301 goes to 0V.
Otherwise, V_IO.
• This Folder signal is delivered to DBB, and the status of Flip is reported.
Folder Signal Status
• L : Close (Magnetized)
• H : Open (Not magnetized)
V_IO
V_IO
C316
C317
0.1u
0.1u
- 63 -