Safety distance from the wall covering
If a wall covering is installed, a minimum safety distance must be maintained
between the countertop cut-out and the covering, since high temperatures can
damage these materials.
If the covering is made of a flammable material (such as wood), the minimum
distance  between the countertop cut-out and the wall covering must be 50 mm
(2" ).
For coverings made of non-flammable materials (such as metal, natural stone,
ceramic tiles) the minimum safety distance  between the countertop cut-out and
the wall covering is equal to 50 mm (2") minus the thickness of the covering.
For example: thickness of wall covering 15 mm (
50 mm (2") - 15 mm (
Flush-mounted cooktops
a Masonry
b Wall covering dimension x = thickness of wall covering
c Countertop
d Countertop cut-out
e Minimum distance to
flammable materials: 50 mm (2")
non-flammable materials: 50 mm (2") - dimension x
3
/
") = minimum distance of 35 mm (1 
16
3
/
")
16
7
/
")
16
Cooktops with trim or bevelled
Installation
edges
57