Summary of Contents for National Instruments NI 9775

  • Page 1 (217) 352-9330 | Click HERE Find the National Instruments NI 9775 at our website:...
  • Page 2 GETTING STARTED GUIDE NI 9775 4-Ch, ±10 V, 20 MS/s, 14-Bit Digitizer hnology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www...
  • Page 3: Safety Guidelines

    This document explains how to connect to the NI 9775. Before you begin, complete the software and Note hardware installation procedures in your chassis documentation. The guidelines in this document are specific to Note the NI 9775. The other components in the system might not meet the same safety ratings.
  • Page 4: Safety Voltages

    III, or IV. Safety Guidelines for Hazardous Locations The NI 9775 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2, AEx nA IIC T4 and Ex nA IIC T4 hazardous locations; and nonhazardous NI 9775 Getting Started Guide | ©...
  • Page 5 IEC/EN 60079-15. Special Conditions for Hazardous Locations Use in Europe and Internationally The NI 9775 has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO 12 ATEX 1202658X and is IECEx UL 14.0089X certified. Each NI 9775 is marked II 3G and is suitable for use in Zone 2 hazardous locations, in ambient temperatures of -40 °C...
  • Page 6: Electromagnetic Compatibility Guidelines

    ≤ Ta ≤ 70 °C. If you are using the NI 9775 in Gas Group IIC hazardous locations, you must use the device in an NI chassis that has been evaluated as Ex nC IIC T4, Ex IIC T4, Ex nA IIC T4, or Ex nL IIC T4 equipment.
  • Page 7 If unshielded cables or accessories are 6 | ni.com | NI 9775 Getting Started Guide hnology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www...
  • Page 8 EMC performance is attained. NI 9775 Getting Started Guide | © National Instruments | 7 hnology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www...
  • Page 9: Preparing The Environment

    Preparing the Environment Ensure that the environment in which you are using the NI 9775 meets the following specifications. Operating temperature -40 °C to 70 °C (IEC 60068-2-1, IEC 60068-2-2) Operating humidity 10% RH to 90% RH, (IEC 60068-2-78) noncondensing...
  • Page 10 NI 9775 Pinout CHASSIS CHASSIS CHASSIS CHASSIS NI 9775 Getting Started Guide | © National Instruments | 9 hnology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www...
  • Page 11 Signal Description Analog input signal connection CHASSIS GND Chassis ground connection Single-Ended Connections – CHASSIS GND Source NI 9775 10 | ni.com | NI 9775 Getting Started Guide hnology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www...
  • Page 12: Overvoltage Protection

    NI 9775 Connection Guidelines Make sure that devices you connect to the NI 9775 are compatible with the module specifications. Overvoltage Protection The NI 9775 provides overvoltage protection for each channel. Refer to the device datasheet on ni.com/manuals Note for more information about overvoltage protection.
  • Page 13: Where To Go Next

    LabVIEW Help RELATED INFORMATION C Series Documentation Services ni.com/services & Resources ni.com/info cseriesdoc Located at ni.com/manuals Installs with the software 12 | ni.com | NI 9775 Getting Started Guide hnology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www...
  • Page 14: Worldwide Support And Services

    If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration. NI 9775 Getting Started Guide | © National Instruments | 13 hnology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www...
  • Page 15 U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. © 2016 National Instruments. All rights reserved. 377101A-01 Nov16...

Table of Contents